Dacor MRES30S Installation Instructions - Page 3

Electrical Power Supply - 30

Page 3 highlights

Electrical Power Supply Requirements Product Dimensions It is the owner's responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric Code ANSI/NFPA 70-2002* (or latest revision) and local codes and ordinances. *A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 Optional full size side panel The correct voltage, frequency and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse. 60" (1524mm) long 240 Vac 4 wire conduit location Dedicated Electrical Circuit Required 120/240Vac, 4-wire, 60Hz., 50 Amp. Total Connected Load 10.3kW (48.2 Amp.) Electrical Requirements The above electrical specifications are for reference only. See the range data plate for exact specifications. See page 1 for location. WARNING: If the electric service provided does not meet the product specifications, do not proceed with the installation. Call the selling dealer or a licensed electrician. NOTE: If the appliance is connected to a 120/208 volt power supply, preheat times and cavity temperature recovery times will be increased slightly. Removable (factory installed) 3" (76mm) side panels Dimensions - Isometric View 30" (762mm) Range top 23 1/2" (597mm) Rear of control Panel/oven door 25 5/16" (643mm) Door opened Max. depth to oven door handle with door closed 45 1/4" (1149mm) Dimensions - Top View 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

2
Electrical Power Supply
Requirements
It is the owner’s responsibility to ensure
that the electrical connection of this
appliance is performed by a qualified
electrician. The electrical installation,
including minimum supply wire size and
grounding, must be in accordance with
the National Electric Code ANSI/NFPA
70-2002* (or latest revision) and local
codes and ordinances.
*A copy of this standard may be obtained
from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and
amperage must be supplied to the
appliance from a separate, grounded,
circuit that is protected by a properly sized
circuit breaker or time delay fuse.
Dedicated
Electrical
Circuit Required
Total
Connected
Load
120/240Vac,
4-wire, 60Hz., 50 Amp.
10.3kW (48.2 Amp.)
Electrical Requirements
The above electrical specifications are for
reference only. See the range data plate
for exact specifications. See page 1 for
location.
WARNING:
If the electric service provided
does not meet the product
specifications, do not proceed
with the installation. Call the
selling dealer or a licensed
electrician.
NOTE:
If the appliance is connected
to a 120/208 volt power supply,
preheat times and cavity
temperature recovery times will
be increased slightly.
Optional full
size side panel
Removable (factory installed)
3” (76mm) side panels
60” (1524mm) long
240 Vac 4 wire
conduit location
Dimensions - Isometric View
Product Dimensions
Door opened
Range top
23 1/2"
(597mm)
25 5/16"
(643mm)
Rear of control
Panel/oven door
Max. depth
to oven door
handle with
door closed
30"
(762mm)
45 1/4"
(1149mm)
Dimensions - Top View