Dacor RNRP36G Installation Instructions - Page 5
Planning the Installation - lp
![]() |
View all Dacor RNRP36G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Planning the Installation WARNING • IMPORTANT: Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner's responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician. The appliance installation must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70: Electrical Requirements • The range is supplied with a factory installed, 6 foot long, power cord with a three-prong grounding plug. It is connected to the chassis at the rear of the range. It must be connected to a dedicated, grounded three-prong electrical outlet. • The correct voltage, frequency and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse. Model Circuit Required Total Connected Load* RNRP36G 120 Vac, 60 Hz, 15 Amp. 120 Vac 60 Hz, 5.0 Amp. RNRP48G 120 Vac, 60 Hz, 15 Amp. 120 Vac 60 Hz, 8.0 Amp. *These specifications for reference only. Refer to the rating label for exact specifications (see below for location). Gas Supply Requirements • The installation of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. • Be certain that the appliance being installed is correct for the gas service provided (natural gas or LP gas). Also, if operating the range at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. Refer to the range rating label and the table on the inside cover to determine the correct model. • See the table below for gas supply pressure requirements. • The range comes from the factory with the regulator installed. Use only the installed regulator. The regulator inlet accommodates a 3/4" gas line. The range ships with a 1/2" to 3/4" adapter connected to the regulator. GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Minimum Minimum Gas Manifold Pressure Supply Pressure** Natural Gas 5" Water Column 6" Water Column Liquid Propane (LP) 10" Water Column 11" Water Column * The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure. ** Maximum gas supply pressure for all models: 1/2 psi. The ratings above are for reference only. Refer to the rating label for exact specifications (see below left for location). View rating label through slot on top of kick panel through opening between door and range Specifications Label Location Gas Inlet A Power cord B GAS - ELECTRICAL ACCESS DIMENSIONS Model A B RNRP36G 13 1/16" to 14 3/8" (33.2 to 36.5 cm) 7 5/16" (18.6 cm) RNRP48G 13 1/16" to 14 3/8" (33.2 to 36.5 cm) 4 1/4" (10.8 cm) 3
![](/manual_guide/products/dacor-rnrp48g-installation-instructions-456b090/5.png)