Dacor RNRP36G Installation Instructions - Page 8
Preparing for Installation
![]() |
View all Dacor RNRP36G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Installation Instructions Preparing for Installation WARNING • If the gas or electric service provided does not meet the product specifications, do not proceed with the installation. Call the dealer, the gas supplier or a licensed electrician. • Before installing the range, you must locate and secure the anti-tip bracket to the floor. IMPORTANT: Within the Commonwealth of Massachusetts, this appliance must be installed by a licensed plumber or gas fitter. Unpacking the Range Unpack the parts box and verify that all required components have been provided. If any item is missing or damaged, please contact your dealer immediately. Do not install a damaged or incomplete appliance. Parts List - 3 Grates - 8 Standard burner caps (4 brass, 4 porcelain)* - 4 Standard burner rings - 4 SimmerSear burner caps (2 brass, 2 porcelain)* - 2 SimmerSear burner rings - 2 SimmerSear burner heads - 2 GlideRack™ oven racks - 1 Standard rack - 2 GlideRack™ 18" wide oven racks (RNRP48G only) - Knobs (4 Standard cooktop, 2 cooktop MAX GRIDDLE, 1 oven for RNRP36G, 2 oven for RNRP48G) - Anti-tip bracket with screws and anchors - Griddle - Wok ring - Stainless steel cleaner - Literature kit - Broiler pan/grill - 1 18" wide standard oven rack (RNRP48G only) *The range is supplied with two different types of burner caps (brass and porcelain) to suit the customer's preference. Please note that the brass burner caps change color over time as the result of heat. Installing a 9 Inch Backguard (Optional) Install the optional 9 inch backguard before making the range gas and electrical connections. Install it according the installation instructions included with the backguard kit. Approved backguard kits: Model APB36D9 APB48D9 Description 9 inch high backguard for range model RNRP36G 9 inch high backguard for range model RNRP48G Install the Anti-Tip Bracket and Foot Locate the anti-tip bracket included in the parts box. There are two ways to mount the anti-tip bracket: • Floor mounting (preferred method) • Wall mounting (alternate method). Use this method if floor mounting is not suitable. If the front panel of range (excluding bull nose) is further than 27" (68.6 cm) from the back wall or if the flooring is too thick (see Installing the Anti-Tip Bracket on the Wall), the wall mounting method may not be used and the floor mounting method must be suitable. Installing the Anti-Tip Bracket on the Floor WARNING To perform its intended function, the anti-tip bracket must be attached as instructed to the concrete slab or wood sub-floor below any floor coverings (including cement board) on top. Do not attach the anti-tip bracket directly to floor coverings such as ceramic/asphalt tile or linoleum. Floor covering Anti-tip bracket Sub-floor Screws attached to sub-floor below floor covering Concrete anchors shown, do not use for wood sub-floor Four (4) plastic anchors are provided along with three sizes (4 each) of #8 or #12 Phillips head screws for attaching the antitip bracket to the floor. Use both the anchors and four (4) of the screws when attaching the bracket to a concrete sub-floor. Do not use the provided anchors when attaching to a wood sub-floor. 6
![](/manual_guide/products/dacor-rnrp48g-installation-instructions-456b090/8.png)