Dacor RV36 Planning Guides

Dacor RV36 Manual

Dacor RV36 manual content summary:

  • Dacor RV36 | Planning Guides - Page 1
    30" (762 mm) 36" (914 mm) 46" (1168 mm) B - Chassis Width 27 3/8" (695 mm) 33 3/8" (848 mm) 43 3/8" (1102 mm) A B Product data label Adjustable anchor legs Front View NOTES: 1. Install these raised vents only with approved Dacor cooktops. See the planning guide for the particular appliance
  • Dacor RV36 | Planning Guides - Page 2
    blower installation instructions. Failure to do so may result in a fire or safety hazard. ■■ Install the raised vent, blower and cooktop so that they can be removed if service is required. ■■ Refer to the cooktop planning guide for the minimum cutout dimensions specific to the particular raised vent
  • Dacor RV36 | Planning Guides - Page 3
    and 45° adjustable elbow Cooktop Revised 03/29/10 Page 3/7 PLANNING GUIDE REMP16 Series Remote Blower Wall Board Backsplash Duct work between raised vent and remote blower 90° Elbow Raised Vent with internal cabinet blower mounted to front Raised vent configured for bottom exhaust Gas
  • Dacor RV36 | Planning Guides - Page 4
    from raised vent to in-line blower Duct work Duct work ILHSF series in-line blower Example of Layout with in-line Blower, Duct Work Under Floor, wall Exhaust Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor
  • Dacor RV36 | Planning Guides - Page 5
    reduce the air draw by the raised vent. You must install one of the Dacor blower models listed below for proper operation. For models REMP3 or REMP16, see the REMP3/16 Remote Blower Installation Instructions. For model CABP3, see the instructions later in this manual. Only one blower shall be
  • Dacor RV36 | Planning Guides - Page 6
    Document # PG08-003 RV30, RV36, RV46 30", 36", 46" Wide, Raised Vent Planning the Duct Work (continued) Raised vent Countertop center line Revised 03/29/10 Page 6/7 PLANNING GUIDE Duct connection A center line 14 3/8"  (365 mm)   CL 1 7/8" *   (48 mm) CL 25 5/8" (651 mm)  
  • Dacor RV36 | Planning Guides - Page 7
    RV36, RV46 30", 36", 46" Wide, Raised Vent Revised 03/29/10 Page 7/7 PLANNING GUIDE Calculating the Maximum Duct Run Length ■■ Do not use duct work meters) Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
8.7
RV30, RV36, RV46
26 3/4"
(679 mm)
1/2” (13 mm)
thick stiffener
across back
4 5/8" (117 mm)
9 7/8” (251 mm)
with CABP3
blower installed
Vent shown
in raised
position
Product
data label
2 5/16"
(59 mm)
9/16"
(14 mm)
3 1/8"
(79 mm)
2"
(51 mm)
B
A
Adjustable
anchor legs
1 13/16"
(46 mm)
1 15/16"
(49 mm)
3/16"
(5 mm)
Top cap with
vent down
7" (178 mm)
7 1/2" (191 mm)
Front View
15/16" (24 mm)
28"
(711 mm)
to
34"
(864 mm)
Model
Number
A - Top Cap
Width
B - Chassis
Width
RV30
30” (762 mm)
27 3/8” (695 mm)
RV36
36” (914 mm)
33 3/8” (848 mm)
RV46
46” (1168 mm)
43 3/8” (1102 mm)
All tolerances: +1/16”, -0,
(+1.6 mm, -0) unless otherwise stated
NOTES:
Install these raised vents only with approved Dacor
1.
cooktops. See the planning guide for the particular
appliance for proper applications and cutout information.
This appliance must be install in conjunction with a
2.
single Dacor approved cabinet, remote or in-line blower.
See following pages for approved blowers. For detailed
information on the remote
and in-line blowers,
refer to the blower’s installation instructions.
Document # PG08-003
Revised 03/29/10
Page 1/7
WARNING
Observe all governing codes and ordinances
during planning and installation. Contact your
local building department for further information.
This appliance must be installed in accordance
with the accompanying installation instructions.
30”, 36”, 46” Wide,
Raised Vent