Dacor RV36 Planning Guides - Page 2

, 46 Wide, Raised Vent - installation

Page 2 highlights

RV30, RV36, RV46 Document # PG08-003 30", 36", 46" Wide, Raised Vent Revised 03/29/10 Page 2/7 PLANNING GUIDE Electrical Specifications WARNING The electric service for the raised vent should be installed only by a licensed electrician. It is the owner's responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA 70- 2002* (or latest revision) and local codes and ordinances. *A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 Electrical Requirements Power must be supplied by a separate, grounded, single phase circuit protected by a properly sized circuit breaker or time delay fuse and rated at 120 Vac, 60 Hz, 15 Amps. ■■ The above specifications are for reference only. If the power supply requirements shown above do not agree with those listed on the product data label, use the ratings on the label. ■■ The suggested location of the junction box supplying power to the unit is to the bottom right of the unit, providing local codes permit. ■■ Install 3 conductor wiring/conduit with minimum current carrying capacity of 8 Amps to supply power to the internal cabinet blower or remote blower from the raised vent when turned on. ■■ When installing a remote or in-line blower run the wiring/ conduit parallel to the duct work and connect it to the remote blower and raised vent on the ends. There are two 7/8" access holes in the bottom of the raised vent for connecting the wiring to the blower and connecting the vent to the power supply junction box. General System Layout The vent system consists of the raised vent itself and a single Dacor approved remote blower or internal cabinet blower. Raised Vent Model No. RV30 RV36 RV46 Approved Blowers CABP3, ILHSF8, ILHSF10, REMP3, REMP16 Duct Sizes 3 1/4"x10", 8" round, 10" round WARNING • Failure to install an approved blower and proper duct work will result in a back draft and/or the insufficient venting of smoke and fumes. • To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the cooktop should be avoided. • Follow the instructions and diagrams for minimum safe clearances and installation location in these instructions, the appliance installation instructions and the blower installation instructions. Failure to do so may result in a fire or safety hazard. ■■ Install the raised vent, blower and cooktop so that they can be removed if service is required. ■■ Refer to the cooktop planning guide for the minimum cutout dimensions specific to the particular raised vent model being installed. ■■ The raised vent is equipped with adjustable anchor legs to accommodate various cabinet heights. ■■ All contact surfaces between the raised vent and any cabinets or walls must be solid and at right angles. Cabinet blower Connection to cabinet blower Connection to junction box Electrical access holes in bottom Electrical Layout Connection to remote/in-line blower Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 8.8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
8.8
RV30, RV36, RV46
Electrical Specifications
WARNING
The electric service for the raised vent should be
installed only by a licensed electrician.
It is the owner’s responsibility to ensure that the electrical connection of this
appliance is performed by a qualified electrician. The electrical installation,
including minimum supply wire size and grounding, must be in accordance
with the National Electric code ANSI/NFPA 70- 2002* (or latest revision) and
local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
Electrical Requirements
Power must be supplied by a separate, grounded, single phase circuit
protected by a properly sized circuit breaker or time delay fuse and rated at
120 Vac, 60 Hz, 15 Amps.
The above specifications are for reference only. If the power supply
requirements shown above do not agree with those listed on the
product data label, use the ratings on the label.
The suggested location of the junction box supplying power to the unit
is to the bottom right of the unit, providing local codes permit.
Install 3 conductor wiring/conduit with minimum current carrying
capacity of 8 Amps to supply power to the internal cabinet blower or
remote blower from the raised vent when turned on.
When installing a remote or in-line blower run the wiring/ conduit
parallel to the duct work and connect it to the remote blower and
raised vent on the ends. There are two 7/8” access holes in the
bottom of the raised vent for connecting the wiring to the blower and
connecting the vent to the power supply junction box.
General System Layout
The vent system consists of the raised vent itself and a single Dacor
approved remote blower or internal cabinet blower.
Raised Vent
Model No.
Approved Blowers
Duct Sizes
RV30
CABP3, ILHSF8, ILHSF10,
REMP3, REMP16
3 1/4”x10”,
8” round,
10” round
RV36
RV46
WARNING
Failure to install an approved blower and proper duct work
will result in a back draft and/or the insufficient venting of
smoke and fumes.
To reduce the risk of personal injury caused by reaching
over a hot appliance, cabinet storage space located directly
above the cooktop should be avoided.
Follow the instructions and diagrams for minimum safe
clearances and installation location in these instructions, the
appliance installation instructions and the blower installation
instructions. Failure to do so may result in a fire or safety
hazard.
Install the raised vent, blower and cooktop so that they can be
removed if service is required.
Refer to the cooktop planning guide for the minimum cutout
dimensions specific to the particular raised vent model being installed.
The raised vent is equipped with adjustable anchor legs to
accommodate various cabinet heights.
All contact surfaces between the raised vent and any cabinets or
walls must be solid and at right angles.
Cabinet blower
Connection to
cabinet blower
Electrical access
holes in bottom
Connection to
remote/in-line
blower
Connection to
junction box
Document # PG08-003
Revised 03/29/10
Page 2/7
30”, 36”, 46” Wide,
Raised Vent
ELECTRICAL LAYOUT