Dacor SGM304 Planning Guides - Page 3

Planning, Guide - specifications

Page 3 highlights

Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 3/5 PLANNING GUIDE Cabinet and Countertop Layout WARNING • To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop. • Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. • Follow the countertop manufacturer's instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc. ◊ Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. ◊ This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system. Cabinet tolerances: +1/16" (+1.6 mm), -0, unless otherwise stated A Combustible overhead cabinets 13" max.3 (33.0 cm) 18" min.1, 3 (45.7 cm) Combustible surface to rear See cutout dimensions 30" min.1, 2 (76.2 cm) 1 7/8" min. (4.8 cm) ◊ Allow a minimum 1/4" (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop. 1/4" (6 mm) min. clearance to combustible B surfaces Under Cabinet Clearances Model (B) Minimum* SGM304 29" (73.7 cm) SGM365 35 ¼" (89.5 cm) SGM466 46" (116.8 cm) * To allow clearance for hold down brackets ◊ The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it. The installation must allow for the following: ◊ Access to the gas shut-off valve and regulator when the unit is installed. ◊ Access to the electrical outlet when the cooktop is in place. The 40" (101.6 cm) power cord must be able to reach the electrical outlet ◊ Access to the underside of the cooktop for service and inspection purposes ◊ Clearance inside the cabinet to allow for proper hold down bracket installation. To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions. Raised Vent Compatibility If installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below: 7 1/2" (19.1 cm) min. to combustible side wall, above counter both sides 1 Measured from cooking surface (top of cooktop grate). 2 If installing with an overhead vent hood, also check hood specifications for minimum required clearances. 3 Not applicable for cabinets more than a horizontal distance of 6" (15.2 cm) from edge of cooktop. Allow 7 1/2" (19.1 cm) from edge of cutout. Minimum Required Clearances Around the Cooktop Cooktop Models SGM304 SGM365 SGM466 Approved Raised Vent Models ERV30, PRV30 or RV30 ERV36, PRV36 or RV36 PRV46 or RV46 Model SGM304 SGM365 SGM466 (A) Minimum 30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm) (A) Recommended 36" (91.4 cm) 42" (106.7 cm) 54" (137.2 cm) Specifications subject to change without notice. www.Dacor.com Phone: (800) 7934-0.7093

  • 1
  • 2
  • 3
  • 4
  • 5

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.Dacor.com
SGM304, SGM365, SGM466
Allow a minimum 1/4” (6 mm) clearance between the bottom of the
cooktop chassis and all combustible surfaces, including the upper
edge of a drawer installed below the cooktop.
Model
(B) Minimum*
SGM304
29” (73.7 cm)
SGM365
35 ¼” (89.5 cm)
SGM466
46” (116.8 cm)
* To allow clearance for hold down brackets
The gas supply piping, gas shut-off valve and the electrical outlet
must be located so they do not interfere with the cooktop when it is
installed. If installing another appliance in the
cabinet below, allow for
the routing of gas and electrical service behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator when the unit is
installed.
Access to the electrical outlet when the cooktop is in place. The 40”
(101.6 cm) power cord must be able to reach the electrical outlet
Access to the underside of the cooktop for service and inspection
purposes
Clearance inside the cabinet to allow for proper hold down bracket
installation.
To allow access to the utilities and cooktop bottom, a fixed shelf should
not be installed below the cooktop. See the following pages for countertop
cutout dimensions.
Raised Vent Compatibility
If installing the cooktop with a raised vent, install only the approved Dacor
model numbers specified below:
Cooktop Models
Approved Raised Vent Models
SGM304
ERV30, PRV30 or RV30
SGM365
ERV36, PRV36 or RV36
SGM466
PRV46 or RV46
Cabinet and Countertop Layout
WARNING
To reduce the risk of personal injury caused by reaching over
a hot appliance, avoid locating cabinet storage space directly
above the cooktop.
Failure to meet or exceed the maximum and minimum
dimensions/clearances stated in these instructions may result
in a fire hazard.
Follow the countertop manufacturer’s instructions regarding
the minimum corner radius, use of heat reflective tape,
reinforcement of corners, etc.
Carefully check the location where the cooktop will be installed. For
best performance, the cooktop should be placed away from drafts that
may be caused by doors, windows and heating and air conditioning
outlets.
This appliance is to be used in conjunction with a suitable vent hood
or approved Dacor raised vent system.
MINIMUM REQUIRED CLEARANCES AROUND THE COOKTOP
Model
(A) Minimum
(A) Recommended
SGM304
30” (76.2 cm)
36” (91.4 cm)
SGM365
36” (91.4 cm)
42” (106.7 cm)
SGM466
48” (121.9 cm)
54” (137.2 cm)
1/4” (6 mm)
min. clearance
to combustible
surfaces
B
Under Cabinet Clearances
13" max.
3
(33.0 cm)
3
Not applicable for cabinets more than a horizontal distance of 6”
(15.2 cm) from edge of cooktop. Allow 7 1/2”
(19.1 cm)
from edge
of cutout.
A
See cutout
dimensions
18" min.
1
,
3
(45.7 cm)
1 7/8" min.
(4.8 cm)
Combustible
surface to rear
Combustible overhead
cabinets
30" min.
1
,
2
(76.2 cm)
7 1/2” (19.1 cm) min. to
combustible side wall,
above counter both sides
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
1
Measured from cooking surface (top of cooktop grate).
Cabinet tolerances: +1/16” (+1.6 mm), -0,
unless otherwise stated
Document # PG04-004
Revised 01/27/11
Page 3/5
30”, 36”, 46” Wide,
Gas Cooktops