Dacor SGM304 Planning Guides - Page 4
Cutout Dimensions - sgm304s 30 gas cooktop
View all Dacor SGM304 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 4/5 PLANNING GUIDE Cutout Dimensions Cutout tolerances +1/16" (+1.6 mm), -0, unless otherwise noted IMPORTANT: Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cutting the countertop. Countertop Dimensions Installation Type Cutout Diagram (C) Min. (D) (E) (F) SGM304 without raised vent Figure 1 (Square) 2 7/8" (7.3 cm) 19 3/4" (50.2 cm) 27 3/4" (68.6 cm) NA SGM304 with ERV30 or PRV30 SGM304 with RV30 SGM365 without raised vent SGM365 with ERV36 or PRV36 SGM365 with RV36 SGM466 without raised vent SGM466 with PRV46 SGM466 with RV46 Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 2 (Notched) Figure 2 (Notched) 3/8" (1.0 cm) 5/8" (1.6 cm) 2 7/8" (7.3 cm) 3/8" (1.0 cm) 5/8" (1.6 cm) 2 7/8" (7.3 cm) 3/8" (1.0 cm) 5/8" (1.6 cm) 22 1/2" * (57.2 cm) 22 1/4" * (56.5 cm) 19 3/4" (50.2 cm) 22 1/2" * (57.2 cm) 22 1/4" * (56.5 cm) 19 3/4" (50.2 cm) 22 1/2" * (57.2 cm) 22 1/4" * (56.5 cm) 27 3/4" (68.6 cm) 27 3/4" (68.6 cm) 33 5/8" (85.4 cm) 33 5/8" (85.4 cm) 33 5/8" (85.4 cm) 44 3/4" (113.7 cm) 44 3/4" (113.7 cm) 44 3/4" (113.7 cm) NA NA NA NA NA NA 43 1/2" (110.5 cm) 43 1/2" (110.5 cm) * Total cutout depth, accommodates both the cooktop and raised vent ** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D). (G) NA NA NA NA NA NA NA 5/8" (1.6 cm) 5/8" (1.6 cm) (H) NA NA NA NA NA NA NA 2 5/8" ** (6.7 cm) 2 5/8" ** (6.7 cm) Stiffener 3/8" min. (1.0 cm) flat countertop overhang required behind cutout Countertop SGM series cooktop Cabinet face 3/8" min. (1.0 cm) space behind raised vent chassis to clear stiffener ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit Floor Side View - sgm Series Cooktop with ERV OR PRV Series Raised Vent Stiffener 5/8" min. (1.6 cm) flat countertop overhang required behind cutout Countertop SGM series cooktop Cabinet face 5/8" min. (1.6 cm) space behind raised vent chassis to clear stiffener RV series raised vent: Check raised vent dimensions/specifications to determine proper fit 4 5/8" (11.7 cm) 9 7/8" (25.1 cm) with CABP3 blower installed Floor Side View - sgm Series Cooktop with RV Series Raised Vent Specifications subject to change without notice. www.Dacor.com Phone: (800) 7934-0.8093