Dacor SGM304 Planning Guides - Page 4

Cutout Dimensions - sgm304s 30 gas cooktop

Page 4 highlights

Document # PG04-004 SGM304, SGM365, SGM466 30", 36", 46" Wide, Gas Cooktops Revised 01/27/11 Page 4/5 PLANNING GUIDE Cutout Dimensions Cutout tolerances +1/16" (+1.6 mm), -0, unless otherwise noted IMPORTANT: Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cutting the countertop. Countertop Dimensions Installation Type Cutout Diagram (C) Min. (D) (E) (F) SGM304 without raised vent Figure 1 (Square) 2 7/8" (7.3 cm) 19 3/4" (50.2 cm) 27 3/4" (68.6 cm) NA SGM304 with ERV30 or PRV30 SGM304 with RV30 SGM365 without raised vent SGM365 with ERV36 or PRV36 SGM365 with RV36 SGM466 without raised vent SGM466 with PRV46 SGM466 with RV46 Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 2 (Notched) Figure 2 (Notched) 3/8" (1.0 cm) 5/8" (1.6 cm) 2 7/8" (7.3 cm) 3/8" (1.0 cm) 5/8" (1.6 cm) 2 7/8" (7.3 cm) 3/8" (1.0 cm) 5/8" (1.6 cm) 22 1/2" * (57.2 cm) 22 1/4" * (56.5 cm) 19 3/4" (50.2 cm) 22 1/2" * (57.2 cm) 22 1/4" * (56.5 cm) 19 3/4" (50.2 cm) 22 1/2" * (57.2 cm) 22 1/4" * (56.5 cm) 27 3/4" (68.6 cm) 27 3/4" (68.6 cm) 33 5/8" (85.4 cm) 33 5/8" (85.4 cm) 33 5/8" (85.4 cm) 44 3/4" (113.7 cm) 44 3/4" (113.7 cm) 44 3/4" (113.7 cm) NA NA NA NA NA NA 43 1/2" (110.5 cm) 43 1/2" (110.5 cm) * Total cutout depth, accommodates both the cooktop and raised vent ** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D). (G) NA NA NA NA NA NA NA 5/8" (1.6 cm) 5/8" (1.6 cm) (H) NA NA NA NA NA NA NA 2 5/8" ** (6.7 cm) 2 5/8" ** (6.7 cm) Stiffener 3/8" min. (1.0 cm) flat countertop overhang required behind cutout Countertop SGM series cooktop Cabinet face 3/8" min. (1.0 cm) space behind raised vent chassis to clear stiffener ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit Floor Side View - sgm Series Cooktop with ERV OR PRV Series Raised Vent Stiffener 5/8" min. (1.6 cm) flat countertop overhang required behind cutout Countertop SGM series cooktop Cabinet face 5/8" min. (1.6 cm) space behind raised vent chassis to clear stiffener RV series raised vent: Check raised vent dimensions/specifications to determine proper fit 4 5/8" (11.7 cm) 9 7/8" (25.1 cm) with CABP3 blower installed Floor Side View - sgm Series Cooktop with RV Series Raised Vent Specifications subject to change without notice. www.Dacor.com Phone: (800) 7934-0.8093

  • 1
  • 2
  • 3
  • 4
  • 5

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.Dacor.com
SGM304, SGM365, SGM466
Cutout tolerances +1/16” (+1.6 mm), -0, unless otherwise noted
Countertop Dimensions
Installation Type
Cutout
Diagram
(C) Min.
(D)
(E)
(F)
(G)
(H)
SGM304
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304
with ERV30 or PRV30
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM304
with RV30
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
27 3/4”
(68.6 cm)
NA
NA
NA
SGM365
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365
with ERV36 or PRV36
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM365
with RV36
Figure 1
(Square)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
33 5/8”
(85.4 cm)
NA
NA
NA
SGM466
without raised vent
Figure 1
(Square)
2 7/8”
(7.3 cm)
19 3/4”
(50.2 cm)
44 3/4”
(113.7 cm)
NA
NA
NA
SGM466
with PRV46
Figure 2
(Notched)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)
SGM466
with RV46
Figure 2
(Notched)
5/8”
(1.6 cm)
22 1/4” *
(56.5 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
Stiffener
Cabinet face
Countertop
Floor
5/8” min. (1.6 cm) space
behind raised vent
chassis to clear stiffener
4 5/8” (11.7 cm)
9 7/8” (25.1 cm) with
CABP3 blower installed
5/8” min. (1.6 cm)
flat countertop overhang
required behind cutout
RV series raised vent:
Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
Cutout Dimensions
SIDE VIEW - SGM SERIES COOKTOP WITH
ERV OR PRV SERIES RAISED VENT
SIDE VIEW - SGM SERIES COOKTOP WITH
RV SERIES RAISED VENT
IMPORTANT:
Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double
check all dimensions against the table below and the correct diagram before cutting the countertop.
* Total cutout depth, accommodates both the cooktop and raised vent
**
IMPORTANT:
Notch depth is included in total cutout depth (D).
DO NOT
add notch depth to total cutout depth (D).
Document # PG04-004
Revised 01/27/11
Page 4/5
30”, 36”, 46” Wide,