Installation Specifications Electrical Requirements Gas Supply Requirements warning To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner's responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician. • The cooktop is supplied with a factory installed, 40-inch, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician. • The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269-9101 • The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference. • Be certain to locate the electrical outlet so that the power cord may be easily disconnected if the unit needs service. Front of unit Product data label Gas inlet Electric cord Chassis Bottom Diagram • Be certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. • Units equipped for LP operation have "LP" in the model number listed on the product data label. See the Chassis Bottom Diagram for label location. • Units equipped for high altitude operation have an "H" at the end of the model number listed on the product data label. • Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. • An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance. • The cooktop comes from the factory with a regulator in the shipping carton. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve. Use only the regulator provided. • Models SGM304 and SGM365 come with a 1/2" regulator. Model SGM466 comes with a 3/4" regulator, approved for connection to a 1/2" house gas supply. The cooktop gas connection is located on the bottom of the cooktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page. Gas type Manifold pressure Min. gas supply pressure ** Max. gas supply pressure Total connected load Circuit requirement SGM304 SGM365 SGM466 Natural gas 4" Water column 5" Water column 1/2 p.s.i. 0.25 Amp. (0.03 kW) 120 Vac, 60 Hz, 15 Amp. SGM304LP SGM365LP SGM466LP LP gas 10" Water column 11" Water column 1/2 p.s.i. 0.25 Amp. (0.03 kW) 120 Vac, 60 Hz, 15 Amp. Gas and Electrical Requirements* * The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label. ** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

4
Electrical Requirements
WARNING
To prevent an electric shock hazard, the power supply
must meet the specifications stated below. It is the own-
er’s responsibility to make sure that the electrical service
meets electrical requirements and that the electrical outlet
has been properly installed by a licensed electrician.
The cooktop is supplied with a factory installed,
40-inch, three-prong, grounding electrical plug. It is
connected to the chassis at the bottom right rear corner
(see
Chassis Bottom Diagram
below). It must be con-
nected to a dedicated, grounded three-prong electrical
outlet installed by a licensed electrician.
The electrical installation, including minimum supply
wire size and grounding, must be done in accordance
with National Electric Code ANSI/NFPA 70* and local
codes and ordinances. A copy of this standard may be
obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
The correct voltage, frequency and amperage must be
supplied to the electrical outlet according to the product
data label located on the bottom of the chassis. See
the
Gas and Electrical Requirements
table on this
page for reference.
Be certain to locate the electrical outlet so that the
power cord may be easily disconnected if the unit
needs service.
Gas Supply Requirements
Be certain that the cooktop being installed is correct for
the gas service being provided (natural gas or LP gas).
Also, if operating the cooktop at an altitude above 4000
ft. (1219 m) make sure it is equipped for high altitude
operation.
Units equipped for LP operation have “LP” in the
model number listed on the product data label. See the
Chassis Bottom Diagram
for label location.
Units equipped for high altitude operation have an “H”
at the end of the model number listed on the product
data label.
Check your local building codes for the proper method
of installation. In the absence of local codes, this
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54.
An external manual shut-off valve must be installed
between the gas inlet and the cooktop for the purpose
of turning on or shutting off gas to the appliance.
The cooktop comes from the factory with a regulator in
the shipping carton. The regulator must be installed in
the gas line that runs from the cooktop gas inlet to the
gas shut off valve. Use only the regulator provided.
Models SGM304 and SGM365 come with a 1/2” regu-
lator. Model SGM466 comes with a 3/4” regulator,
approved for connection to a 1/2” house gas supply.
The cooktop gas connection is located on the bottom of the
cooktop in the back right corner as you face the front of the
unit. See the
Chassis Bottom Diagram
on this page.
SGM304
SGM365
SGM466
SGM304LP
SGM365LP
SGM466LP
Gas type
Natural gas
LP gas
Manifold
pressure
4” Water
column
10” Water
column
Min. gas supply
pressure **
5” Water
column
11” Water
column
Max. gas supply
pressure
1/2 p.s.i.
1/2 p.s.i.
Total connected
load
0.25 Amp.
(0.03 kW)
0.25 Amp.
(0.03 kW)
Circuit
requirement
120 Vac,
60 Hz, 15 Amp.
120 Vac,
60 Hz, 15 Amp.
Gas and Electrical Requirements*
*
The electrical and gas data on this page is for reference
only. If the above data does not agree with the product data
label, use the data on the product data label.
** The gas supply pressure for testing the regulator setting
shall be at least 1 inch water column (249 Pa) above the
specified manifold pressure.
Front of unit
Product data label
Electric cord
Gas inlet
Chassis Bottom Diagram
Installation Specifications