Installation Specifications Cabinet and Countertop Layout warning • To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop. • Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. • Follow the countertop manufacturer's instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc. • Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. • This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system. All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. A Combustible overhead cabinets 13" max.3 (33.0 cm) 18" min.1, 3 (45.7 cm) Combustible surface to rear See cutout dimensions 30" min.1, 2 (76.2 cm) 1 7/8" min. (4.8 cm) 7 1/2" (19.1 cm) min. to combustible side wall, above counter both sides 1 Measured from cooking surface (top of cooktop grate). 2 If installing with an overhead vent hood, also check hood specifications for minimum required clearances. 3 Not applicable for cabinets more than a horizontal distance of 6" (15.2 cm) from edge of cooktop. Allow 7 1/2" (19.1 cm) from edge of cutout. Minimum Required Clearances Around the Cooktop • Allow a minimum 1/4" (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop. 1/4" (6 mm) min. clearance to combustible B surfaces Under Cabinet Clearances Model B: Minimum* SGM304 SGM365 SGM466 29" (73.7 cm) 35 1/4" (89.5 cm) 46" (116.8 cm) * To allow clearance for hold down brackets • The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it. The installation must allow for the following: • Access to the gas shut-off valve and regulator when the unit is installed. • Access to the electrical outlet when the cooktop is in place. The 40" (101.6 cm) power cord must be able to reach the electrical outlet. • Access to the underside of the cooktop for service and inspection purposes. • Clearance inside the cabinet to allow for proper hold down bracket installation. To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions. Raised Vent Compatibility If installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below: Cooktop Models SGM304 SGM365 SGM466 Approved Raised Vent Models ERV30, PRV30 or RV30 ERV36, PRV36 or RV36 PRV46 or RV46 Model SGM304 SGM365 SGM466 A: Minimum 30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm) A: Recommended 36" (91.4 cm) 42" (106.7 cm) 54" (137.2 cm) 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

5
Cabinet and Countertop Layout
WARNING
To reduce the risk of personal injury caused by
reaching over a hot appliance, avoid locating cabinet
storage space directly above the cooktop.
Failure to meet or exceed the maximum and mini-
mum dimensions/clearances stated in these instruc-
tions may result in a fire hazard.
Follow the countertop manufacturer’s instructions
regarding the minimum corner radius, use of heat
reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be
installed. For best performance, the cooktop should be
placed away from drafts that may be caused by doors,
windows and heating and air conditioning outlets.
This appliance is to be used in conjunction with a suit-
able vent hood or approved Dacor raised vent system.
Model
A: Minimum
A: Recommended
SGM304
30” (76.2 cm)
36” (91.4 cm)
SGM365
36” (91.4 cm)
42” (106.7 cm)
SGM466
48” (121.9 cm)
54” (137.2 cm)
Installation Specifications
Allow a minimum 1/4” (6 mm) clearance between the
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed
below the cooktop.
Model
B: Minimum*
SGM304
29” (73.7 cm)
SGM365
35 1/4” (89.5 cm)
SGM466
46” (116.8 cm)
* To allow clearance for hold down brackets
The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so they do not interfere
with the cooktop when it is installed. If installing another
appliance in the cabinet below, allow for the routing of
gas and electrical service behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator when
the unit is installed.
Access to the electrical outlet when the cooktop is in
place. The 40” (101.6 cm) power cord must be able to
reach the electrical outlet.
Access to the underside of the cooktop for service and
inspection purposes.
Clearance inside the cabinet to allow for proper hold
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed
shelf should not be installed below the cooktop. See the fol-
lowing pages for countertop cutout dimensions.
Raised Vent Compatibility
If installing the cooktop with a raised vent, install only the
approved Dacor model numbers specified below:
Cooktop Models
Approved Raised Vent Models
SGM304
ERV30, PRV30 or RV30
SGM365
ERV36, PRV36 or RV36
SGM466
PRV46 or RV46
1/4” (6 mm)
min. clearance
to combustible
surfaces
B
Under Cabinet Clearances
13" max.
3
(33.0 cm)
3
Not applicable for cabinets more than a horizontal distance of 6”
(15.2 cm) from edge of cooktop. Allow 7 1/2”
(19.1 cm)
from edge
of cutout.
A
See cutout
dimensions
18" min.
1
,
3
(45.7 cm)
1 7/8" min.
(4.8 cm)
Combustible
surface to rear
Combustible overhead
cabinets
30" min.
1
,
2
(76.2 cm)
7 1/2” (19.1 cm) min. to
combustible side wall,
above counter both sides
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
1
Measured from cooking surface (top of cooktop grate).
All tolerances +1/16” (+1.6 mm), -0
unless otherwise noted.
Minimum Required Clearances Around the Cooktop