Danby DDR5011 Product Manual - Page 7

Operating, Instructions, Cont'd

Page 7 highlights

OPERATING INSTRUCTIONS (cont'd) START OPERATION 1) Place the product in an upright position on a flat, stable, and heatresistant surface. Make sure there is nothing flammable or heat sensitive within 100cm (39 inches). Operating the product in any other position could cause a hazard. 2) Insert the plug into a suitable wall socket. The dehumidifier is suitable for operating on an electricity supply having the same voltage as that shown on its rating label. 3) Make sure the water tank is correctly located. After switching on the machine for the first time, if the "Bucket Full" light illuminates, pull out the water tank and check that the "float" lever is able to move freely, then return the water tank to the correct position (Fig. 1). Fig. 1 WATER FULL When the water tank is full and/or incorrectly positioned inside the cabinet, the water INDICATOR full red light turns on and remains on until such time that the tank is emptied and/or LIGHT (RED)j correctly re-positioned. This condition will result in the immediate shut down of the dehumidifying system (both compressor and fan motor operations are terminated). This is a safety feature. When the water tank is emptied and/or correctly re-positioned, the dehumidifier will resume operation automatically. NOTE: It may take several minutes before operating conditions resume. BUCKET FULL LIGHT • When the water tank is full the machine will stop and the"Bucket Full" light will illuminate • The water tank should be carefully removed from the machine by sliding it outward from the front of the unit, and it should be emptied. When the empty tank is replaced properly in the machine, the unit will start up and run normally (Fig. 2). NOTE: Please use both hands to carefully empty the water tank. Fig. 2 FACTORY DEFAULT SETTING Each time the unit is disconnected/re-connected and/or in the event of a power failure, the electronic circuitboard automatically defaults to the following factory setting: Humidity Setting: 60% Fan Speed: Low NOTE: In the event of a power failure, the unit will default to the last program setting that was used when power is restored. WOAPETRERATTIAONNK Proper. installation of the water tank is crucial in maintaining reliable dehumidifier operation. The water tank holds accumulated condensed water and: by means of a safety switch, controls both the water level and operation of the dehumidification process. When the water tank is full and/or accidentally displaced inside the cabinet, the float switch actuator (inside the tank) breaks contact with the safety switch. This condition results in the immediate shut down of the compressor and fan motor system, preventing moisture from being condensed. NOTE: Never tamper with or attempt to defeat the water level (safety) float switch system.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

OPERATING
INSTRUCTIONS
(cont'd)
START
OPERATION
1)
Place
the
product
in
an
upright
position
on
a
flat,
stable,
and
heat
-
resistant
surface.
Make
sure
there
is
nothing
fl
ammable
or
heat
sensitive
within
100cm
(39
inches).
Operating
the
product
in
any
other
position
could
cause
a
hazard.
2)
Insert
the
plug
into
a
suitable
wall
socket.
The
dehumidifier
is
suitable
for
operating
on
an
electricity
supply
having
the
same
voltage
as
that
shown
on
its
rating
label.
3)
Make
sure
the
water
tank
is
correctly
located.
After
switching
on
the
machine
for
the
fi
rst
time,
if
the
"Bucket
Full"
light
illuminates,
pull
out
the
water
tank
and
check
that
the
"float"
lever
is
able
to
move
freely,
then
return
the
water
tank
to
the
correct
position
(Fig.
1).
Fig.
1
WATER
FULL
When
the
water
tank
is
full
and/or
incorrectly
positioned
inside
the
cabinet,
the
water
INDICATOR
full
red
light
turns
on
and
remains
on
until
such
time
that
the
tank
is
emptied
and/or
LIGHT
(RED)j
correctly
re
-positioned.
This
condition
will
result
in
the
immediate
shut
down
of
the
dehumidifying
system
(both
compressor
and
fan
motor
operations
are
terminated).
This
is
a
safety
feature.
When
the
water
tank
is
emptied
and/or
correctly
re
-positioned,
the
dehumidifier
will
resume
operation
automatically.
NOTE:
It
may
take
several
minutes
before
operating
conditions
resume.
BUCKET
FULL
LIGHT
When
the
water
tank
is
full
the
machine
will
stop
and
the"Bucket
Full"
light
will
illuminate
The
water
tank
should
be
carefully
removed
from
the
machine
by
sliding
it
outward
from
the
front
of
the
unit,
and
it
should
be
emptied.
When
the
empty
tank
is
replaced
properly
in
the
machine,
the
unit
will
start
up
and
run
normally
(Fig.
2).
NOTE:
Please
use
both
hands
to
carefully
empty
the
water
tank.
Fig.
2
FACTORY
Each
time
the
unit
is
disconnected/re-connected
and/or
in
the
event
of
a
power
failure,
DEFAULT
SETTING
the
electronic
circuitboard
automatically
defaults
to
the
following
factory
setting:
Humidity
Setting:
60%
Fan
Speed:
Low
NOTE:
In
the
event
of
a
power
failure,
the
unit
will
default
to
the
last
program
setting
that
was
used
when
power
is
restored.
WATER
TANK
Proper
.
installation
of
the
water
tank
is
crucial
in
maintaining
reliable
dehumidifier
OPERATION
operation.
The
water
tank
holds
accumulated
condensed
water
an
d
:
by
means
of
a
safety
switch,
controls
both
the
water
level
and
operation
of
the
dehumidification
process.
When
the
water
tank
is
full
and/or
accidentally
displaced
inside
the
cabinet,
the
float
switch
actuator
(inside
the
tank)
breaks
contact
with
the
safety
switch.
This
condition
results
in
the
immediate
shut down
of
the
compressor
and
fan
motor
system,
preventing
moisture
from
being
condensed.
NOTE:
Never
tamper
with
or
attempt
to
defeat
the
water
level
(safety)
fl
oat
switch
system.