Page 6 highlights
Step-by-Step Installation (continued) Hole location options and requirements • Mounting in ceiling with joists 16" on-center. - Place template against inside edge of joist. - Trace around template with pencil. - Cut hole. See Diagram 1, page 9 for reference. • Mounting in ceiling with joists wider than 16" on-center. - Place template at least 11/4" away from existing joists (to clear lock arms). - Template does not need to be centered between joists. - Trace around template with pencil. - Cut hole. - Install framing material inside cavity, running 90 degrees to existing joists, leaving 141/2" between frame sides. See Diagram 2, page 9 for reference. • Mounting in ceiling with joists 16" on-center where crossbeam is closer than 11/4" from side of enclosure. - Enclosure MUST be against the crossbeam and 2 joists, boxing it in on 3 sides. Shim as required. - This will require 2 additional #8 x 31/2" wood screws and side gasket material (not included) to secure to crossbeam and prevent rattling. - Place template against crossbeam and mounting joist. - Trace around template with pencil. - Cut hole. 6 See Diagram 3, page 10 for reference.