Power Supplies On both the S50N and S50V, either the AC or DC power supplies alone are sufficient to power the switch. When both AC and DC power supplies are connected, they act in roughly a 60%/40% load-sharing mode. WARNING: To prevent electrical shock, make sure the system is grounded properly. If you do not ground your equipment correctly, excessive emissions may result. Use a qualified electrician to ensure that the power cables meet your local electrical requirements. Fans Ventilation is side-to-side, with six fans on the left side of the switch as you face the PSU side. The fan speed increases when the temperature reaches 72 degrees C, and decreases to normal speed when the temperature falls to 57 degrees C. The switch never intentionally stops managing traffic. Status logging is identified by unit in the system log. Fan replacement in the field is not offered as an option. Specifications Chassis Physical Design Parameter S50N and S50N-DC Specifications Height 1.73 inches (4.4 cm) Width 17.32 inches (44.0 cm) (19" rack-mountable) Depth 16.73 inches (42.5 cm) (standard 1 rack unit) Chassis weight with factory-installed components 14.41 pounds (approx.) (6.54 kg) Rack clearance required Front: 5-inches (12.7 cm) Rear: 5-inches (12.7 cm) S50V Specifications 1.73 inches (4.4 cm) 17.32 inches (44.0 cm) (19" rack-mountable) 16.73 inches (42.5 cm) (standard 1 rack unit) 14.41 pounds (approx.) (6.54 kg) Front: 5-inches (12.7 cm) Rear: 5-inches (12.7 cm) 10 Installing the Hardware

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

10
Installing the Hardware
Power Supplies
On both the S50N and S50V, either the AC or DC power supplies alone are
sufficient to power the switch. When both AC and DC power supplies are
connected, they act in roughly a 60%/40% load-sharing mode.
WARNING: To prevent electrical shock, make sure the system is grounded
properly. If you do not ground your equipment correctly, excessive emissions
may result. Use a qualified electrician to ensure that the power cables meet
your local electrical requirements.
Fans
Ventilation is side-to-side, with six fans on the left side of the switch as you face
the PSU side.
The fan speed increases when the temperature reaches 72 degrees C, and
decreases to normal speed when the temperature falls to 57 degrees C. The
switch never intentionally stops managing traffic.
Status logging is identified by unit in the system log.
Fan replacement in the field is not offered as an option.
Specifications
Chassis Physical Design
Parameter
S50N and S50N-DC
Specifications
S50V Specifications
Height
1.73 inches (4.4 cm)
1.73 inches (4.4 cm)
Width
17.32 inches (44.0 cm) (19"
rack-mountable)
17.32 inches (44.0 cm) (19"
rack-mountable)
Depth
16.73 inches (42.5 cm)
(standard 1 rack unit)
16.73 inches (42.5 cm)
(standard 1 rack unit)
Chassis weight with
factory-installed
components
14.41 pounds (approx.) (6.54
kg)
14.41 pounds (approx.) (6.54
kg)
Rack clearance
required
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)