Dell Force10 S25N-S50N Dell Force10 S50N and S50V Systems Quick Start Guide - Page 16

Connect the RJ-45/DB-9 adapter that is shipped with the S50V system to the RJ, cable.

Page 16 highlights

Step Task 1 Install the RJ-45 copper cable that is shipped with the S50V system into the console port. CAUTION: You must install a straight-through RJ-45 copper cable (a standard Ethernet cable) into the console port. This is different from many other implementations that require an Ethernet crossover cable (or rollover cable). If connecting to a terminal server and using a crossover cable, daisychain another crossover cable to effectively get a straightthrough cable connection. Many console terminal servers use octopus cables that are crossover cables. To accommodate the octopus cable, connect an additional crossover cable, as above, to effectively install a straight-through cable. 2 If necessary, connect the RJ-45/DB-9 adapter that is shipped with the S50V system to the end of the RJ-45 cable that will connect to your terminal. 3 Set your initial console terminal settings to match the default console settings on the switch. 9600 baud rate No parity 8 data bits 1 stop bit No flow control (console port only) After establishing a connection, you can modify the settings to match at each end of the connection. Accessing the Console Port Connect the RJ-45/DB-9 adapter that is shipped with the S50V system to the RJ45 cable. Table 2-1. Pin Assignments for Console Port Signal NC NC RXD RJ-45 Pinout 1 2 3 14 Installing the Software

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

14
Installing the Software
Accessing the Console Port
Connect the RJ-45/DB-9 adapter that is shipped with the S50V system to the RJ-
45 cable.
Step
Task
1
Install the RJ-45 copper cable that is shipped with the S50V system into the
console port.
CAUTION: You must install a straight-through RJ-45 copper cable
(a standard Ethernet cable) into the console port. This is different from
many other implementations that require an Ethernet crossover cable (or
rollover cable). If connecting to a terminal server and using a crossover
cable, daisychain another crossover cable to effectively get a straight-
through cable connection. Many console terminal servers use octopus
cables that are crossover cables. To accommodate the octopus cable,
connect an additional crossover cable, as above, to effectively install a
straight-through cable.
2
If necessary, connect the RJ-45/DB-9 adapter that is shipped with the S50V
system to the end of the RJ-45 cable that will connect to your terminal.
3
Set your initial console terminal settings to match the default console settings on
the switch.
9600 baud rate
No parity
8 data bits
1 stop bit
No flow control (console port only)
After establishing a connection, you can modify the settings to match at each
end of the connection.
Table 2-1.
Pin Assignments for Console Port
Signal
RJ-45 Pinout
NC
1
NC
2
RXD
3