Dell OptiPlex NX1 Diagnostics and Troubleshooting Guide (.pdf) - Page 36
Run the System Set Test Group in the Dell Diagnostics. See
View all Dell OptiPlex NX1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Table 2-2. System Beep Codes (continued) Code Cause Action 5-1-2 BIOS update error-no RAM in system See "Troubleshooting System Memory" in Chapter 6. 5-1-3 BIOS update error-external video card detected If a video expansion card is installed, disconnect the video expansion card and connect the monitor to the built-in video subsystem. If the problem is not resolved, see "Troubleshooting the Video Subsystem" in Chapter 6. 5-1-4 BIOS execution error Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-1-2 I/O controller failure Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-1-3 Keyboard controller failure Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-1-4 CMOS Register Test failure Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-2-1 BIOS shadowing failure Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-2-2 Pentium speed determination failure Run the System Set Test Group in the Dell Diagnostics. See Chapter 4, "Running the Dell Diagnostics." 6-2-3 No SIMM or DIMM installed See "Troubleshooting System Memory" in Chapter 6. NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the Index. 2-12 Diagnostics and Troubleshooting Guide