Dell PowerConnect 2824 User's Guide - Page 168
Parameters range, Command Mode, Default value, Usage Guidelines, Examples, no answer from host
View all Dell PowerConnect 2824 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 168 highlights
• hostname - Hostname to ping. • packet_size - Number of bytes in a packet. The default is 56 bytes. The actual packet size will be eight bytes larger than the size specified because the switch adds header information. • packet_count - Number of packets to send, from 1 to 65535 packets. The default is 4 packets. If 0 is entered it pings until stopped. • time_out - Timeout in milliseconds to wait for each reply, from 50 to 65535 milliseconds. The default is 2000 milliseconds. Parameters range • hostname - 1 - 158 characters (Max label size: 63) • packet_size - IPv4: 56 - 1472 • packet_count - 0 - 65535 • time_out - 50 - 65535 Command Mode EXEC Default value This command has no default setting. Usage Guidelines Press Esc to stop pinging. Following are sample results of the ping command: Destination does not respond-If the host does not respond, a "no answer from host" appears in ten seconds. Destination unreachable-The gateway for this destination indicates that the destination is unreachable. Network or host unreachable-The switch found no corresponding entry in the route table. Examples Console> ping 10.1.1.1 Pinging 10.1.1.1 with 64 bytes of data: 64 bytes from 10.1.1.1: icmp_seq=0. time=11 ms 64 bytes from 10.1.1.1: icmp_seq=1. time=8 ms 64 bytes from 10.1.1.1: icmp_seq=2. time=8 ms 64 bytes from 10.1.1.1: icmp_seq=3. time=7 ms 168 Dell PowerConnect 28xx Systems User Guide