Dell PowerConnect B-RX Multi-Service IronWare Software Release 02.8.00a Releas - Page 20
Upgrading the monitor and boot images on the interface module
View all Dell PowerConnect B-RX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Table 7: Command syntax for upgrading IronWare image on the management module Command syntax Description copy tftp flash Copies the images from the TFTP server to the primary or primary | secondary secondary locations in flash memory. copy tftp slot1 | slot2 primary | secondary copy slot1 | slot2 flash primary | secondary Copies the images from a flash card to the primary or secondary locations in flash memory. copy slot1 | slot2 slot1 | slot2 Copies the images from a flash card in slot 1 or slot 2 to another flash card in slot 1 or slot 2. For example, to copy the management module's Ironware image from TFTP server 10.10.12.12 to flash memory, enter the following command. BigIron RX# copy tftp flash 10.10.12.12 rmpr02800a.bin primary 3. Verify that the new IronWare image has been successfully copied to the specified destination by entering one of the following commands at the Privileged EXEC level of the CLI: BigIron RX# show flash (if the destination was code flash) BigIron RX# dir // (if the destination was slot 1 or slot 2) Check for the primary or secondary image and the date and time that it was placed in the directory. 4. If you want to upgrade other software images, go to the appropriate upgrade section for information. If you have completed upgrading the software images, you must reboot the management module to complete the upgrade process. For more information, see Rebooting the management module. Upgrading the monitor and boot images on the interface module Note: We recommend that you perform this upgrade procedure from a PC or terminal that is directly connected to the management module console port. You can also perform this procedure using a Telnet or SSHv2 session. To upgrade monitor and boot images simultaneously on an interface module, perform the following steps: 1. Place the new monitor and boot images on a TFTP server to which the BigIron RX system has access or on a PCMCIA flash card inserted in slot 1 or slot 2. 2. Copy the new monitor and boot images to the BigIron RX. Enter one of the following commands at the Privileged EXEC level of the CLI (For example: BigIron RX#): IronWare Software Release 02.8.00a for Brocade BigIron RX Series Swtches Release Notes v 1.0 Page 20 of 40