- Page 1
Dell™ Systems Server Module Board Replacement www.dell.com | support.dell.com - Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 2
to hardware or loss of data and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potential for property damage, personal injury the entities claiming the marks and names or their products. Dell Computer Corporation disclaims any proprietary interest in trademarks and trade names other - Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 3
add another hard drive and configure a mirror at a later time unless you found and ran the utility then. To replace a server module board, perform the following steps: 1 Remove the server module from the system. See "Removing a Server Module" in the system Service Manual. 2 Replace the server module - Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 4
changes and exit System Setup. Otherwise, just exit System Setup. 11 Boot the server module to the PERC 4/im DOS Utility diskette in the USB diskette drive. The PERC 4/im DOS utility starts automatically. 12 If the server module was configured with mirrored hard drives before the server module board - Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 5
hard drives recently failed, the hard drives do not contain hard drive signatures, or the hard drives contain invalid signatures. a Remove the PERC 4/im DOS Utility diskette from the USB diskette drive. b Reboot the server module. c If the server module does not boot to the operating system, switch - Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 6
www.dell.com | support.dell.com Verifying the Mirror on a Server Module Running Red Hat Linux 7.3 1 Log in as root. 2 Type cat/proc/scsi/scsi. • If the command returns the phrase Module: VIRTUAL DISK in the output, you have a synchronized mirror. For example: Attached devices: Host: scsi0 - Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 7
SCSI ID. The drive with the lowest SCSI ID is /dev/sda, the next lowest ID is /dev/sdb, and so on. For example, when examining the output of the cat /proc/scsi/scsi command in step 2 for a server with two hard drives, the hard drive with ID 0 is /dev/sda, while the hard drive with ID 1 is - Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 8
www.dell.com | support.dell.com 1-6 Ser ver Module Board Replacement - Dell PowerEdge 1655MC | Server Module Board Replacement (Restoring - Page 9
- Dell PowerEdge 1655MC | Server
Module Board Replacement (Restoring
- Page 10
Printed in the U.S.A. 09Y408A00 P/N 9Y408 Rev. A00 www.dell.com | support.dell.com