Table 1-1. System Messages (continued) Message Causes Corrective Actions PCIe Training Error: Slot n Faulty or improperly installed PCIe card in the specified slot. Reseat the PCIe card in the specified slot number. See "Expansion Cards" in the Hardware Owner's Manual. If the problem persists, see "Getting Help" in the Hardware Owner's Manual. Remote Access Controller cable error or incorrect card in the RAC slot. RAC cables not connected, Check that the RAC cables or RAC card installed in are connected, and that the wrong expansion slot. RAC card is installed in the correct expansion slot. See "Installing a RAC Card" in the Hardware Owner's Manual. NOTE: All TPM information messages appear after the BMC option ROM has been loaded during POST. TPM configuration System now resets. operation honored. Information only. TPM Failure A Trusted Platform Module See "Getting Help" in the (TPM) function has failed. Hardware Owner's Manual. TPM operation is pending. Press I to Ignore or M to Modify to allow this change and reset the system. WARNING: Modifying could prevent security. Configuration change has been requested. Press I to continue system boot. Press M to modify the TPM setting and restart. Warning: Following faulty DIMMs are disabled: DIMM n1 n2 Total memory size is reduced. Faulty or improperly See "Troubleshooting seated memory module(s). System Memory" in the DIMMs are disabled in Hardware Owner's Manual. pairs, as indicated by the n1 and n2. Check both DIMMs for a possible fault. Information Update 13