ROMB Batt, PS AC Current, PCI PERR - romb battery
View all Dell PowerEdge 2950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Table 1-2. LCD Status Messages (continued) Code E1211 Text ROMB Batt Causes RAID battery is either missing, bad, or unable to recharge due to thermal issues. E1625 E1711 PS AC Current PCI PERR B## D## F## PCI PERR Slot # Power source is out of acceptable range. The system BIOS has reported a PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##. The system BIOS has reported a PCI parity error on a component that resides in the specified PCIe slot. Corrective Actions Reseat the RAID battery connector. See the "RAID Battery" and see "Troubleshooting System Cooling Problems" in the Hardware Owner's Manual. Check the AC power source. Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting an Expansion Card" in the Hardware Owner's Manual. Reinstall the expansioncard riser. See "Expansion Card Risers" in the Hardware Owner's Manual. If the problem persists, the riser card or system board is faulty. See "Getting Help" in the Hardware Owner's Manual. 16 Information Update