Dell PowerEdge M820 8/4 Gbps FC SAN Module Administrator's Guide - Page 34
Enabling and disabling Failover on an external port (N_Port), ag --failovershow 13
View all Dell PowerEdge M820 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
3 Failover Example 1 Blade Servers FC SAN Module Blade_1 F_1 Blade_2 F_2 N_1 Blade_3 F_3 N_2 Blade_4 F_4 Blade_5 F_5 N_3 Blade_6 F_6 N_4 Blade_7 F_7 Fabric Edge Switch (Switch_A) F_A1 NPIV enabled F_A2 NPIV enabled Edge Switch (Switch_B) F_B1 NPIV enabled F_B2 NPIV enabled Example 2 Blade Servers Blade_1 FC SAN Module F_1 Blade_2 F_2 N_1 Blade_3 F_3 N_2 Blade_4 F_4 Blade_5 F_5 N_3 Blade_6 F_6 N_4 Blade_7 F_7 Fabric Edge Switch (Switch_A) F_A1 NPIV enabled F_A2 NPIV enabled Edge Switch (Switch_B) F_B1 NPIV enabled F_B2 NPIV enabled Blade_8 F_8 Blade_8 F_8 FIGURE 5 Example 1 and 2 Failover behavior Legend Physical connection Mapped online Failover route online Original mapped route (offline) Enabling and disabling Failover on an external port (N_Port) Use the following steps to enable or disable failover policy on an external port. 1. Connect to the FC SAN Module and log in using an account assigned to the admin role. 2. Enter the ag --failovershow n_portnumber command to display the failover setting. switch:admin> ag --failovershow 13 Failover on N_Port 13 is not supported 3. Enter the ag --failoverenable n_portnumber command to enable failover. switch:admin> ag --failoverenable 13 Failover policy is enabled for port 13 4. Enter the ag --failoverdisable n_portnumber command to disable failover. switch:admin> ag --failoverdisable 13 Failover policy is disabled for port 13 20 Dell 8/4Gbps FC SAN Module Administrator's Guide 53-1001345-01