Dell PowerEdge M820 8/4 Gbps FC SAN Module Administrator's Guide - Page 73
The status of FC Fastwrite ON or OFF., Gbps, N4 Gbps, N8 Gbps or AN.
View all Dell PowerEdge M820 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
portShow B Port part of other AD Yes or No. portSpeed The port's fixed speed (1, 2, 4, or 8 Gbps) or negotiated speed (N1 Gbps, N2 Gbps, N4 Gbps, N8 Gbps or AN). LE domain The LE domain ID. FC Fastwrite The status of FC Fastwrite (ON or OFF). If the port is configured as an EX_Port, the following additional port information is displayed: EX_Port Mode The port is configured as an EX_Port. Fabric ID The fabric ID assigned to this EX_Port; this is the fabric ID of the edge fabric attached to this EX_Port. Front Phantom Information on the front phantom domain presented by this EX_Port. Includes the preferred (if not active) or actual (if active) domain ID for the front domain and the WWN of the front domain. Pr Switch Info Information on the principal switch of the edge fabric attached to this EX_Port. Includes the domain ID and WWN of the principal switch. BB XLate Information on the xlate (translate) phantom domain presented at this port. Includes the preferred (if not active) or actual (if active) domain ID for the xlate phantom domain and the WWN of the xlate phantom domain. The xlate phantom domain connected at this port is in the same fabric as the router and represents the edge fabric connected to the EX_Port. Authentication Type Displays NONE or DH-CHAP. DH-CHAP is the only authentication type supported on EX_Ports. DH Group Displays DH group [0-4] if DH-CHAP authentication is used. Otherwise displays N/A. Hash Algorithm Displays hash type (MD5 or SHA-1) if DH-CHAP authentication is used. Otherwise, displays N/A. Edge fabric's primary WWN If the EX_Port is connected to an edge switch with FCS policy enforcement, the WWN of the primary FCS is displayed when the edge fabric is secure and the primary FCS is online. Otherwise, displays "No Primary". Edge fabric's version stamp If the EX_PORT is connected to an edge switch with FCS policy enforcement, the version of the security database is displayed. Otherwise displays N/A. If the port is configured as a VE_Port, the command shows FC and Physical layer attributes of the underlying port, as well as status information regarding the underlying FCIP link for those logical FC ports that are instantiated over a physical 1/10GbE port. Refer to the example section for an illustration. Following the general information, the command displays three columns of counters. The first column shows interrupt statistics: Interrupts Total number of interrupts. Unknown Interrupts that are not counted elsewhere. Dell 8/4Gbps FC SAN Module Administrator's Guide 59 53-1001345-01