5. PCIe SSD is not supported. 6. NVDIMM are not supported. 7. DCPMMs are not supported. Thermal PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate temperature thereby reducing server noise and power consumption. The sensors in the MX740c interact with the chassis management services module which regulates fan speed. All fans which cool the MX740c are contained in the MX7000 chassis. Thermal management of PowerEdge MX740c delivers high performance for the right amount of cooling to components at the lowest fan speeds across a wide range of ambient temperatures from 10°C to 35°C (50°F to 95°F) and to extended ambient temperature ranges (see Environmental Specifications section). The benefits to you are lower fan power consumption (lower server system power and data center power consumption) and greater acoustical versatility. For detailed information about thermal please consult the MX7000 Technical Guide. Table 16. Thermal restriction matrix Ambient Support 25 ° C CPU No restriction 30 ° C No restriction 35 ° C No restriction (The recommended operating temperature for processors with Thermal Design Power (TDP) > 165W is under 32°C) 40 ° C ~ 45 ° C Expanded Operating Temperature Does not support processor with TDP > 140W Does not Support Gold 6146 Gold 6144 Gold 6134 Gold 6132 Gold 6128 Gold 5122 No support for 6234(130W8c), 5217(115W8c) and 5222(105W4c) processors. DIMM Drives Mezzanine Cards No restriction No restriction No restriction No restriction No restriction No restriction No restriction No restriction No restriction Does not support NVDIMM Does not support NVMe (PCIe SSDs) Does not support mezzanine cards with power above 30W 16 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

5.
PCIe SSD is not supported.
6.
NVDIMM are not supported.
7.
DCPMMs are not supported.
Thermal
PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate temperature
thereby reducing server noise and power consumption. The sensors in the MX740c interact with the chassis management services
module which regulates fan speed. All fans which cool the MX740c are contained in the MX7000 chassis.
Thermal management of PowerEdge MX740c delivers high performance for the right amount of cooling to components at the lowest fan
speeds across a wide range of ambient temperatures from 10°C to 35°C (50°F to 95°F) and to extended ambient temperature ranges
(see Environmental Specifications section). The benefits to you are lower fan power consumption (lower server system power and data
center power consumption) and greater acoustical versatility.
For detailed information about thermal please consult the MX7000 Technical Guide.
Table 16. Thermal restriction matrix
Ambient Support
25 ° C
30 ° C
35 ° C
40 ° C ~ 45 ° C
Expanded Operating
Temperature
CPU
No restriction
No restriction
No restriction (The
recommended operating
temperature for
processors with Thermal
Design Power (TDP) >
165W is under 32°C)
Does not support
processor with TDP >
140W
Does not Support Gold
6146 Gold 6144 Gold 6134
Gold 6132 Gold 6128 Gold
5122
No support for
6234(130W8c),
5217(115W8c) and
5222(105W4c)
processors.
DIMM
No restriction
No restriction
No restriction
Does not support
NVDIMM
Drives
No restriction
No restriction
No restriction
Does not support NVMe
(PCIe SSDs)
Mezzanine Cards
No restriction
No restriction
No restriction
Does not support
mezzanine cards with
power above 30W
16
Technical specifications