Page 8 highlights
Table 9. Supported video resolution options (continued) Resolution Refresh rate (Hz) 1600 x 1200 60 1680 x 1050 60 1920 x 1080 60 1920 x 1200 60 Color depth (bits) 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 Environmental specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the manuals & documents on www.dell.com/support/home. Table 10. Operational climatic range category A2 Temperature Specifications Allowable continuous operations Temperature ranges for altitudes
Table 9. Supported video resolution options (continued)
Resolution
Refresh rate (Hz)
Color depth (bits)
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
Environmental specifications
NOTE:
For additional information about environmental certifications, refer to the
Product Environmental Datasheet
located
with the manuals & documents on
www.dell.com/support/home
.
Table 10. Operational climatic range category A2
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)
maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above
900 m (2953 Ft)
Table 11. Operational climatic range category A3
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above
900 m (2953 Ft)
Table 12. Operational climatic range category A4
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating
Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above
900 m (2953 Ft)
Table 13. Shared requirements across all categories
Temperature
Specifications
Allowable continuous operations
8