Dell PowerVault DR6000 Getting Started Guide - Page 7

Power, Physical, Environmental, dell.com/support/manuals, Temperature

Page 7 highlights

Power NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V. Battery Coin-cell battery 3 V CR2032 Lithium coin cell Physical Height Width With rack latches Without rack latches Depth (includes bezel) Weight (maximum) Weight (empty) 87.3 mm (3.44 inch) 482.4 mm (18.98 inch) 444 mm (17.08 inch) 755.8 mm (29.75 inch) 31.86 kg (70.24 lb) 18.78 kg (41.4 lb) Environmental NOTE: Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data centers. For more information, see the Owner's Manual at dell.com/support/manuals. NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Maximum Temperature Gradient (Operating and Storage) 20 °C/h (36 °F/h) Storage Temperature Limits -40 °C to 65 °C (-40 °F to 149 °F) Temperature (Continuous Operation) Temperature Ranges (for altitude less than 950 10 °C to 35 °C (50 °F to 95 °F) with no direct m or 3117 ft) sunlight on the equipment. Humidity Percentage Range 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point. Relative Humidity Storage 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times. Maximum Vibration Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Power
NOTE:
This system is also designed to be
connected to IT power systems with a phase
to phase voltage not exceeding 230 V.
Battery
Coin-cell battery
3 V CR2032 Lithium coin cell
Physical
Height
87.3 mm (3.44 inch)
Width
With rack latches
482.4 mm (18.98 inch)
Without rack latches
444 mm (17.08 inch)
Depth (includes bezel)
755.8 mm (29.75 inch)
Weight (maximum)
31.86 kg (70.24 lb)
Weight (empty)
18.78 kg (41.4 lb)
Environmental
NOTE:
Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data
centers. For more information, see the
Owner's Manual
at
dell.com/support/manuals
.
NOTE:
For additional information about environmental measurements for specific system
configurations, see
dell.com/environmental_datasheets
.
Temperature
Maximum Temperature Gradient (Operating
and Storage)
20 °C/h (36 °F/h)
Storage Temperature Limits
–40 °C to 65 °C (–40 °F to 149 °F)
Temperature (Continuous Operation)
Temperature Ranges (for altitude less than 950
m or 3117 ft)
10 °C to 35 °C (50 °F to 95 °F) with no direct
sunlight on the equipment.
Humidity Percentage Range
10% to 80% Relative Humidity with 26 °C (78.8 °F)
maximum dew point.
Relative Humidity
Storage
5% to 95% RH with 33 °C (91 °F) maximum dew
point. Atmosphere must be non-condensing at all
times.
Maximum Vibration
Operating
0.26 G
rms
at 5 Hz to 350 Hz (all operation
orientations).
7