Dell PowerVault DX6012S Dell DX6012S Hardware Owners Manual - Page 24
Check PSU and, Alert! System
View all Dell PowerVault DX6012S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Message Causes Corrective Actions Alert! Power required exceeds PSU wattage. Check PSU and system configuration. The system configuration of processor(s), memory modules, and expansion cards may not be supported by the power supplies. Alert! Continuing system boot accepts the risk that system may power down without warning. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with High Output power supplies to use the components. See "Power Supplies" on page 80. Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Memory Sparing or Memory Check the memory modules Mirroring was enabled in the for failure. See system setup program, but "Troubleshooting System the current configuration Memory" on page 137. does not support redundant Reset the memory setting, memory. A memory module if appropriate. See "Using may be faulty. the System Setup Program and UEFI Boot Manager" on page 45. Alert! System fatal error during previous boot. An error caused the system to reboot. Check other system messages for additional information for possible causes. BIOS MANUFACTURING MODE detected. MANUFACTURING MODE will be cleared before the next boot. System reboot required for normal operation. System is in manufacturing Reboot to take the system mode. out of manufacturing mode. 24 About Your System