Dell PowerVault DX6012S Dell DX6012S Hardware Owners Manual - Page 36
Warning: A fatal, Warning! No micro
View all Dell PowerVault DX6012S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Message Causes Corrective Actions Unused memory detected. DIMM's installed in the following slot are not available when in 128-bit advanced ECC mode: x,x,x The memory configuration is Reconfigure the memory for not optimal for Advanced Advanced ECC Memory ECC Memory Mode. Mode, or change the Modules in the specified memory mode to Optimized slots are unused. or Sparing in the BIOS setup screen. See "System Memory" on page 83. Warning: A fatal A fatal system error error has caused occurred and caused the system reset! system to reboot. Please check the system event log! Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 129 for any faulty components specified in the SEL. Warning: Control Panel is not installed. The control panel is not Install the control panel, or installed or has a faulty cable check the cable connections connection. between the display module, the control panel board, and the system board. See "Integrated Storage Controller Card" on page 96. Warning! No micro Micro code update failed. code update loaded for processor n Update the BIOS firmware. See "Getting Help" on page 155. 36 About Your System