Dell PowerVault NX200 Troubleshooting Guide - Page 8

Table 1., Installation Issues, Issue, Description, Workaround / Solution, support.dell.com/manuals

Page 8 highlights

Table 1. Installation Issues (continued) Issue Error: -5004. Error occurred while attempting to create OS volume. Error: -5005. Error occurred while attempting to create OS volume. Description Workaround / Solution Drives in the expected system slots dedicated for the operating system are empty. To workaround this issue, perform one of the following steps: • Ensure that all drives in the operating system drive slots are correctly attached and do not have data on them. Physical disks for the operating system must be of the same type and must meet the minimum size requirements. • Enter the PERC BIOS during the operating system boot operation and ensure that there are no foreign configurations, drives are clean of all data, the drives meet the minimum size requirement, and are fully functioning and accessible. For more information, see the PERC documentation at support.dell.com/manuals. Drives in expected operating system slots have existing foreign configurations. To workaround this issue, enter the PERC BIOS during the operating system boot operation and ensure that there are no foreign configurations, drives are clean of all data, the drives meet the minimum size requirement, and are fully functioning and accessible. For more information, see the PERC documentation at support.dell.com/manuals. 8 Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

8
Troubleshooting Guide
Error: -5004.
Error occurred
while
attempting to
create OS
volume.
Drives in the expected
system slots dedicated
for the operating system
are empty.
To workaround this issue, perform
one of the following steps:
Ensure that all drives in the
operating system drive slots are
correctly attached and do not
have data on them. Physical disks
for the operating system must be
of the same type and must meet
the minimum size requirements.
Enter the PERC BIOS during the
operating system boot operation
and ensure that there are no
foreign configurations, drives are
clean of all data, the drives meet
the minimum size requirement,
and are fully functioning and
accessible. For more information,
see the PERC documentation at
support.dell.com/manuals
.
Error: -5005.
Error occurred
while
attempting to
create OS
volume.
Drives in expected
operating system slots
have existing foreign
configurations.
To workaround this issue, enter the
PERC BIOS during the operating
system boot operation and ensure
that there are no foreign
configurations, drives are clean of
all data, the drives meet the
minimum size requirement, and
are fully functioning and
accessible. For more information,
see the PERC documentation at
support.dell.com/manuals
.
Table 1.
Installation Issues
(continued)
Issue
Description
Workaround / Solution