Dell PowerVault Storage MD1280 Dell Storage MD1280 Service Guide - Page 28

LED Indicators, Power Supply Units per PSU, Available Hard Drive Power Per Slot

Page 28 highlights

LED Indicators 6 Gbps SAS I/O module Fan module PSU Power Supply Units (per PSU) Watt Voltage Heat dissipation Maximum inrush current Available Hard Drive Power (Per Slot) Supported hard drive power consumption (continuous) I/O Card Power (Per Slot) Maximum power consumed by I/O Card Maximum available power Maximum available power Physical Height Width 14 one-color LED status indicators, four each for the three SAS ports, and two for the module status • One single-color LED indicator for module status • One single-color LED indicator for battery fault status (not currently used) • One single-color LED indicator for fan fault status • One single-color LED indicator for power status • sOtanteussingle‐color LED indicator for PSU fault • Ostanteussingle‐color LED indicator for AC fault • One single‐color LED indicator for power status 2.8 kW 200-240 VAC (8.6 A-4.3 A) 191-147 W Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A for each PSU for 10 ms or less. Up to 1.16 A at +5 V,  Up to 1.6 A at +12 V 11 W at +12 V 100 W at +12 V 1 W at +5 V (standby) 22.23 cm (8.75 inches) 48.26 cm (19 inches) 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

LED Indicators
6 Gbps SAS I/O module
14 one-color LED status indicators, four each for
the three SAS ports, and two for the module status
Fan module
One single-color LED indicator for module
status
One single-color LED indicator for battery fault
status (not currently used)
One single-color LED indicator for fan fault
status
One single-color LED indicator for power
status
PSU
One single
color LED indicator for PSU fault
status
One single
color LED indicator for AC fault
status
One single
color LED indicator for power status
Power Supply Units (per PSU)
Watt
2.8 kW
Voltage
200–240 VAC (8.6 A–4.3 A)
Heat dissipation
191–147 W
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach 55 A for each PSU for 10 ms or less.
Available Hard Drive Power (Per Slot)
Supported hard drive power consumption
(continuous)
Up to 1.16 A at +5 V,  Up to 1.6 A at +12 V
I/O Card Power (Per Slot)
Maximum power consumed by I/O Card
11 W at +12 V
Maximum available power
100 W at +12 V
Maximum available power
1 W at +5 V (standby)
Physical
Height
22.23 cm (8.75 inches)
Width
48.26 cm (19 inches)
28