6 Access system health sensors To check sensor information, use the following command: root@dellemc-diag-os:~# ipmitool sensor list To change the sensor threshold, see the IPMI Specification v2.0 chapter 35.8 Set Sensor Thresholds Command. ● Request data byte 1-Sensor number, FFH=reserved ● Request data byte 2- ○ [7:6] - reserved. Write as 00b ○ [5] - 1b=set upper non-recoverable threshold ○ [4] - 1b=set upper critical threshold ○ [3] - 1b=set upper non-critical threshold ○ [2] - 1b=set lower non-recoverable threshold ○ [1] - 1b=set lower critical threshold ○ [0] - 1b=set lower non-critical threshold ● Request data byte 3-lower non-critical threshold. Ignored if bit 0 of byte 2 = 0 ● Request data byte 4-lower critical threshold. Ignored if bit 1 of byte 2 = 0 ● Request data byte 5-lower non-recoverable threshold. Ignored if bit 2 of byte 2 = 0 ● Request data byte 6-upper non-critical threshold. Ignored if bit 3 of byte 2 = 0 ● Request data byte 7-upper critical threshold value. Ignored if bit 4 of byte 2 = 0 ● Request data byte 8-upper non-recoverable threshold value. Ignored if bit 5 of byte 2 = 0 ● Response data byte 1-Completion code ipmitool sensors root@dellemc-diag-os:~# ipmitool sensor list PT_Mid_temp | 32.000 | degrees C | ok | na NPU_Near_temp | 29.000 | degrees C | ok | na PT_Left_temp | 28.000 | degrees C | ok | na PT_Right_temp | 30.000 | degrees C | ok | na ILET_AF_temp | 26.000 | degrees C | ok | na PSU1_AF_temp | 24.000 | degrees C | ok | na PSU2_AF_temp | 25.000 | degrees C | ok | na PSU1_temp | 33.000 | degrees C | ok | na PSU2_temp | na | degrees C | na | na CPU_temp | 31.000 | degrees C | ok | na FAN1_Rear_rpm | 9120.000 | RPM | ok | na FAN2_Rear_rpm | 9000.000 | RPM | ok | na FAN3_Rear_rpm | 9000.000 | RPM | ok | na FAN4_Rear_rpm | 9000.000 | RPM | ok | na FAN1_Front_rpm | 10080.000 | RPM | ok | na FAN2_Front_rpm | 10080.000 | RPM | ok | na FAN3_Front_rpm | 10080.000 | RPM | ok | na FAN4_Front_rpm | 10080.000 | RPM | ok | na PSU1_rpm | 9000.000 | RPM | ok | na PSU2_rpm | na | RPM | na | na PSU_Total_watt | 110.000 | Watts | ok | na PSU1_stat | 0x0 | discrete | 0x0180| na PSU2_stat | 0x0 | discrete | 0x0380| na PSU1_In_watt | 110.000 | Watts | ok | na PSU1_In_volt | 205.700 | Volts | ok | na PSU1_In_amp | 0.480 | Amps | ok | na PSU1_Out_watt | 90.000 | Watts | ok | na PSU1_Out_volt | 12.400 | Volts | ok | na PSU1_Out_amp | 7.500 | Amps | ok | na PSU2_In_watt | na | Watts | na | na PSU2_In_volt | na | Volts | na | na PSU2_In_amp | na | Amps | na | na PSU2_Out_watt | na | Watts | na | na PSU2_Out_volt | na | Volts | na | na PSU2_Out_amp | na | Amps | na | na ACPI_stat | 0x0 | discrete | 0x0180| na FAN1_prsnt | 0x0 | discrete | 0x0180| na FAN2_prsnt | 0x0 | discrete | 0x0180| na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | 1080.000 | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | 78.000 | 80.000 | 85.000 | na | na | na | na | na | na | na | na | na | na | na | na | 61.000 | 64.000 | na | na | na | na | na | na | na | na | na | na | 90.000 | 94.000 | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na | na Access system health sensors 33