Dell S5248F-ON EMC Networking Virtualization Overlay with BGP EVPN - Page 20

Factory default configuration, Con switch port profile S4148U-ON only

Page 20 highlights

5.3 5.4 Factory default configuration The switch configuration commands in the chapters that follow begin with the leaf switches at their factory default settings. Dell EMC PowerSwitches running OS10EE can be reset to their default configuration as follows: OS10# delete startup-configuration Proceed to delete startup-configuration [confirm yes/no(default)]:y OS10# reload System configuration has been modified. Save? [yes/no]:n Proceed to reboot the system? [confirm yes/no]:y The switch reboots to its factory default configuration. Note: OS10EE at its default settings has Telnet disabled, SSH enabled, and the OOB management interface configured to get its IP address via DHCP. The default username and password are both admin. Dell EMC recommends changing the admin password to a complex password during the first login. Configure switch port profile (S4148U-ON only) Note: This section is specific to the S4148U-ON switches used as examples in this guide. Port profiles are currently supported on the S4148-ON series of switches and S4148U-ON switches. Disregard this section for other models. See the Switch-port profiles section of OS10 Enterprise Edition User Guide Release 10.4.3.0 for switch-port profile options and details. Four S4148U-ON switches are used as leafs in this deployment example. A switch port profile determines the enabled front-panel ports and supported breakout modes on Ethernet and unified ports. Switch port profile-3 is used in this deployment example to enable four 100GbE ports (two for uplinks to the spines and two for the VLTi) on each S4148U-ON switch. To change the switch port profile from its default setting to profile-3, run the following commands: OS10# configure terminal OS10(config)# switch-port-profile 1/1 profile-3 Warning: Switch port profile will be applied only after a save and reload. All management port configurations will be retained but all other configurations will be wiped out after the reload. OS10(config)# exit OS10# write memory OS10# reload Proceed to reboot the system? [confirm yes/no]:y 20 Dell EMC Networking Virtualization Overlay with BGP EVPN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

20
Dell EMC Networking Virtualization Overlay with BGP EVPN
5.3
Factory default configuration
The switch configuration commands in the chapters that follow begin with the leaf switches at their factory
default settings. Dell EMC PowerSwitches running OS10EE can be reset to their default configuration as
follows:
OS10#
delete startup-configuration
Proceed to delete startup-configuration [confirm yes/no(default)]:
y
OS10#
reload
System configuration has been modified. Save? [yes/no]:
n
Proceed to reboot the system? [confirm yes/no]:
y
The switch reboots to its factory default configuration.
Note:
OS10EE at its default settings has Telnet disabled, SSH enabled, and the OOB management interface
configured to get its IP address via DHCP. The default username and password are both
admin
. Dell EMC
recommends changing the admin password to a complex password during the first login.
5.4
Configure switch port profile (S4148U-ON only)
Note:
This section is specific to the S4148U-ON switches used as examples in this guide. Port profiles are
currently supported on the S4148-ON series of switches and S4148U-ON switches. Disregard this section for
other models. See the
Switch-port profiles
section of
OS10 Enterprise Edition User Guide Release 10.4.3.0
for switch-port profile options and details.
Four S4148U-ON switches are used as leafs in this deployment example. A switch port profile determines the
enabled front-panel ports and supported breakout modes on Ethernet and unified ports. Switch port profile-3
is used in this deployment example to enable four 100GbE ports (two for uplinks to the spines and two for the
VLTi) on each S4148U-ON switch.
To change the switch port profile from its default setting to profile-3, run the following commands:
OS10#
configure terminal
OS10(config)#
switch-port-profile 1/1 profile-3
Warning: Switch port profile will be applied only after a save and reload.
All management port configurations will be retained but all other
configurations will be wiped out after the reload.
OS10(config)#
exit
OS10#
write memory
OS10#
reload
Proceed to reboot the system? [confirm yes/no]:
y