Dewalt DCC2560T1 Instruction Manual - Page 12
How to Use Your Unit Fig. E, MAINTENANCE, Customer Responsibilities
View all Dewalt DCC2560T1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
English 5. Set the Auto On/Off switch to "Auto On" position. Quick-Connect Coupler 9 : The quick connect body accepts industrial quick connect plugs. How to Use Your Unit (Fig. E) How to Stop 1. Set the Auto On/Off switch 1 to "Off". 2. Remove battery when not in use. Before Starting WARNING: Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions. Before Each Start-Up 1. Remove battery. (Refer to Installing and Removing the Battery Pack) 2. Set the Auto On/Off switch 1 to "Off". 3. Turn the regulator 6 counterclockwise to set the outlet pressure to zero. 4. Attach hose and accessories. WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip. WARNING: Risk of unsafe operation. Do not use damaged or worn accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect body 9 . WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer's maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating. NOTICE: Risk of property damage. Compressed air from the unit may contain water condensation and oil mist. Do not spray unfiltered air at an item that could be damaged by moisture. Some air tools and accessories may require filtered air. Read the instruc tions for the air tools and accessories. How to Start 1. Install the battery into the tool. 2. Set the Auto On/Off switch 1 to "Auto On" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 3. Turn regulator 6 clockwise to increase pressure and stop when desired pressure is reached. WARNING: Risk of unsafe operation. If any unusual noise or vibration is noticed, stop the compressor immediately and have it checked by a trained service technician. WARNING: Ensure the regulator is set to a pressure lower than the maximum operating pressure of the tool. The compressor is ready for use. Fig. E 1 6 4 9 MAINTENANCE WARNING: To reduce the risk of serious personal injury, turn unit off and remove the battery pack before making any adjustments or removing/ installing attachments or accessories. An accidental start-up can cause injury. Customer Responsibilities Before each Daily or after See tank use each use warning label Check Safety Valve X Drain Tank X Remove tank from service X*** *** For more information, call 1-800-4-DeWALT (1-800-433-9258) WARNING: Risk of unsafe operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure. NOTE: See Operation section for the location of controls. To Check Safety Valve (Fig. E) WARNING: Risk of Bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. WARNING: Risk from Flying Objects. Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields. Before starting compressor, pull the ring on the safety valve 4 to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve. 10