E Setup 4. View the measurement on the display window (Figure D #2). Attaching the Wrist Strap 1. While facing the front of the tool, insert the thin end of Changing the Unit of Measure the wrist strap through one of the holes in the lower Once the current measurement is taken, you can change right corner of the tool. the unit of measure from decimal ft (6.21 ft) to fractional 2. Push the thin end of the wrist strap until it goes through the other hole. ft (6'02"9/16), fractional ft to meters (1.894 m), meters to inches (74 9/16 in), or inches to decimal ft. 3. Separate the two wires, which make up the thin end of the wrist strap, to form a loop. To change the unit of measurement, press and hold until you see the measurement change (2-3 seconds). 4. Insert the thick end of the wrist strap all the way through the loop in the thin end, so the wrist strap is NOTE: If you continue to hold after the measurement changes, the tool will turn off. securely fastened to the tool (Figure B ). Re-measuring Charging the Battery Fully charge the battery before initial use and whenever the tool has not been used for 6 months or longer. 1. Locate the port cover on the side of the tool (Figure A #4). 2. Using your finger, gently pull the port cover down (Figure E #1). If you need to take a new measurement, click . • The previous measurement (Figure D #2) will be cleared from the display window. • When you are ready to take the new measurement, click . Turning Off the Tool The tool can be turned off in either of these ways: 3. Insert the small end of the USB Recharge Cable into the port on the side of the tool, making sure to insert the flat side of the cable into the flat side of the port (Figure E #2). • After taking a measurement, press and hold for 5 seconds (until the display window clears). • If you do not use the tool for 45 seconds, it will automatically turn off. 4. Insert the USB end of the cable into a USB port in a computer or USB power outlet (Figure E #3). 5. Wait approximately 2.5 hours for the battery to fully charge and then disconnect the USB Recharge Cable. When the tool is ON, the battery level appears in the display window (Figure D #1). Operation 1. Point the laser at the top of the tool (Figure A #1) toward the wall whose distance you need to measure (Figure C #1). 2. Click (Figure A #3) to turn the tool on and display a laser dot on the wall (Figure C #1). 3. When the bottom of the tool is positioned at the correct distance from the wall, click to take the measurement (Figure C #2). 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

4
E
Setup
Attaching the Wrist Strap
1.
While facing the front of the tool, insert the thin end of
the wrist strap through one of the holes in the lower
right corner of the tool.
2.
Push the thin end of the wrist strap until it goes
through the other hole.
3.
Separate the two wires, which make up the thin end
of the wrist strap, to form a loop.
4.
Insert the thick end of the wrist strap all the way
through the loop in the thin end, so the wrist strap is
securely fastened to the tool (Figure
B
).
Charging the Battery
Fully charge the battery before initial use and whenever
the tool has not been used for 6 months or longer.
1.
Locate the port cover on the side of the tool
(Figure
A
#4).
2.
Using your finger, gently pull the port cover down
(Figure
E
#1).
3.
Insert the small end of the USB Recharge Cable into
the port on the side of the tool, making sure to insert
the flat side of the cable into the flat side of the port
(Figure
E
#2).
4.
Insert the USB end of the cable into a USB port in a
computer or USB power outlet (Figure
E
#3).
5.
Wait approximately 2.5 hours for the battery to fully
charge and then disconnect the USB Recharge
Cable.
When the tool is ON, the battery level appears in the
display window (Figure
D
#1).
Operation
1.
Point the laser at the top of the tool (Figure A #1)
toward the wall whose distance you need to measure
(Figure
C
#1).
2.
Click
(Figure
A
#3) to turn the tool on and
display a laser dot on the wall (Figure
C
#1).
3.
When the bottom of the tool is positioned at the
correct distance from the wall, click
to take the
measurement (Figure
C
#2).
4.
View the measurement on the display window
(Figure
D
#2).
Changing the Unit of Measure
Once the current measurement is taken, you can change
the unit of measure from decimal ft (6.21 ft) to fractional
ft (6'02"9/16), fractional ft to meters (1.894 m), meters to
inches (74 9/16 in), or inches to decimal ft.
To change the unit of measurement, press and hold
until you see the measurement change (2-3 seconds).
NOTE: If you continue to hold
after the measurement
changes, the tool will turn off.
Re-measuring
If you need to take a new measurement, click
.
• The previous measurement (Figure
D
#2) will be
cleared from the display window.
When you are ready to take the new measurement,
click
.
Turning Off the Tool
The tool can be turned off in either of these ways:
• After taking a measurement, press and hold
for
5 seconds (until the display window clears).
If you do not use the tool for 45 seconds, it will