EdgeStar AP16000G Owner s Manual - Page 16

Modes

Page 16 highlights

NOTE: The exhaust hose must be used in cooling mode in order to cool a room. Modes AUTO: When selecting auto mode, the air conditioner will operate automatically according to the ambient temperature. The set temperature can't be adjusted unless the mode is switched to cooling. COOL: If the ambient temperature drops below the temperature you selected, the compressor turns off and the unit functions with the fan only. When the temperature rises above the temperature you selected, the compressor turns on again. The Cool Indicator light "insert" will be lit. You can press the "+" or "-" to increase or decrease the set temperature. Whether your desired temperature can actually be reached depends on the ambient conditions. The room temperature remaining above the set temperature is normal. To operate the unit in cooling mode: 1) Make sure the power cord is plugged into a power outlet. 2) Press the ON/OFF button on the remote. 3) Press the Mode button until the Cool Indicator Light on the Control Panel lights up. 4) Select the fan speed by using the Fan button. 5) Set the thermostat by using the "+" and "-" buttons on the remote. The thermostat is adjustable between 61°F - 86°F in one degree increments. DRY: When dry mode (or de-humidify mode) is selected, the air conditioner operates under dry mode at a low fan speed. The Dry Indicator light will be lit. Under dry mode the fan speed can't be adjusted. NOTE: Fan Only mode does not require that the exhaust hose be attached. FAN: Fan Only mode is used to circulate the air in your room. No temperature setting is needed. To operate the unit in Fan Only mode: 1) Make sure the power cord is plugged into a power outlet. 2) Press the ON/OFF button on the remote. 3) Press the Mode button until the Fan Indicator light on the control panel lights up. 4) Press the Fan button to adjust fan speed. Edgestar Portable Air Conditioner 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Edgestar Portable Air Conditioner
12
Modes
AUTO: When selecting auto mode, the air conditioner will operate
automatically according to the ambient temperature. The set
temperature can’t be adjusted unless the mode is switched to
cooling.
COOL: If the ambient temperature drops below the temperature
you selected, the compressor turns off and the unit functions with
the fan only. When the temperature rises above the temperature
you selected, the compressor turns on again. The Cool Indicator
light “insert” will be lit. You
can press the “+” or “
-
“ to increase or
decrease the set temperature.
Whether your desired temperature can actually be reached
depends on the ambient conditions. The room temperature
remaining above the set temperature is normal.
To operate the unit in cooling mode:
1) Make sure the power cord is plugged into a power outlet.
2) Press the ON/OFF button on the remote.
3) Press the Mode button until the Cool Indicator Light on the
Control Panel lights up.
4) Select the fan speed by using the Fan button.
5) Se
t the thermostat by using the “+” and “
-
buttons on the
remote. The thermostat is adjustable between 61°F - 86°F in one
degree increments.
DRY: When dry mode (or de-humidify mode) is selected, the air
conditioner operates under dry mode at a low fan speed. The Dry
Indicator light will be lit
. Under dry mode the fan speed can’t be
adjusted.
FAN:
Fan Only mode is used to circulate the air in your room. No
temperature setting is needed.
To operate the unit in Fan Only mode:
1) Make sure the power cord is plugged into a power outlet.
2) Press the ON/OFF button on the remote.
3) Press the Mode button until the Fan Indicator light on the control
panel lights up.
4) Press the Fan button to adjust fan speed.
NOTE:
The exhaust hose must
be used in cooling mode in order
to cool a room.
NOTE:
Fan Only mode does not
require that the exhaust hose be
attached.