Here are the descriptions of every setup item: Item Description Enable RS-485 Check this box to enable RS-485 functionality. Use Pelco-D Select this option and RS-485 interface will output pan-tile control signal in Pelco-D format. This format is widely accepted by most of pan-tilt camera cradles. You have also input pan-tilt camera cradle's address code in 'Address' field (number must be between 0~255). This code must be identical to pan-tilt camera cradle's address code. Use Custom When the pan-tilt camera cradle does not support Pelco-D Protocol protocol, you can define a protocol's detail by this function. Please refer to pan-tilt camera cradle's user manual to define the protocol. - Baud Rate: Select data baud rate of RS-485 interface that pan-tilt camera cradle will accept. When the length of RS-485 connection is very long (longer than 200M), it's not recommended to use high speed connection (greater than 2400bps). - Data Bits: Select data bits of RS-485 connection. - Parity: Select parity bit: odd, even, or space. - Stop Bit: Select stop bit: 1 or 2. - Home/Up/Down/Left/Right: Input the command string used to move pan-tilt camera cradle to home or up/down/left/right position. You can click 'Test' button to send command string for testing. - Command 1 ~ 5: You can define extra pan-tilt camera cradle control strings here by giving it a name (Command Name) and command string (Hexadecimal Message). You can also click 'Test' button to send command string for testing. When you finish with above settings, click 'Apply' button to save changes. 42