Electrolux E36DF76GPS Installation Instructions - Page 10

Model with Electric Oven and Gas Cooktop - installation guide

Page 10 highlights

30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS (Model with Electric Oven and Gas Cooktop) 11.2 Check Operation Refer to the Use and Care Guide and the Electronic Oven Control Guide packaged with the range for operating instructions and for care and cleaning of your range. Remove all packaging from the oven before testing. 1. Burner Bases and Burner Caps This range is equipped with sealed burners as shown (Figure 17). All pieces are at their place. Take note where they are. Remove all packaging material located under the Dual Surface burner head. Make sure the burner is properly aligned and leveled. NOTE: There are no burner adjustments necessary on this range. 30" Range Burner Cap Burner Cap Burner Base 4. Adjust the "LOW" Setting of Regular Burner (see figure 17) on the Surface Burner Valves (Figure 18): a. Push in and turn control to LITE until burner ignites. b. Quickly turn knob to LOWEST POSITION. c. If burner goes out, reset control to OFF. d. Remove the surface burner control knob and decorative ring. e. Insert a thin-bladed screwdriver into the hollow valve stem and engage the slotted screw inside. Flame size can be increased or decreased by turning the screw. Turn counterclockwise to increase flame size. Turn clockwise to decrease flame size. Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame. Flame should be as small as possible without going out. Note: Air mixture adjustment is not required on surface burners. 36" Range Fixed Burner Ring Fixed Burner Ring and Burner Base Dual Surface Burner Figure 17 Regular Burner 2. Turn on Electrical Power and Open Main Shutoff Gas Valve 3. Check the Igniters Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power. To check for proper lighting: a. Push in and turn a surface burner knob to the LITE position. All electronic surface ignitors will spark at the same time. However, only the burner you are turning on will ignite. b.The surface burner should light once the flow of gas reached the surface burner. Each burner should light within four (4) seconds in normal operation after air has been purged from supply lines. Visually check that burner has lit. c. Once the burner lights, the control knob should be rotated out of the LITE position. There are separate ignition devices for each burner. Try each knob separately until all burner valves have been checked. Figure 18 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

10
30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
(Model with Electric Oven and Gas Cooktop)
Figure 18
4. Adjust the "LOW" Setting of Regular Burner (see
figure 17) on the Surface Burner Valves (Figure 18):
a. Push in and turn control to LITE until burner ignites.
b.
Quickly
turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob and
decorative ring.
e. Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame
size can be increased or decreased by turning the
screw. Turn counterclockwise to increase flame size.
Turn clockwise to decrease flame size. Adjust flame
until you can quickly turn knob from LITE to LOWEST
POSITION without extinguishing the flame. Flame
should be as small as possible without going out.
Note:
Air mixture adjustment is not required on surface
burners.
11.2 Check Operation
Refer to the Use and Care Guide and the Electronic Oven
Control Guide packaged with the range for operating
instructions and for care and cleaning of your range.
Remove all packaging from the oven before testing.
1.
Burner Bases and Burner Caps
This range is equipped with sealed burners as shown
(Figure 17). All pieces are at their place. Take note where
they are.
Remove all packaging material located
under the Dual Surface burner head.
Make sure the
burner is properly aligned and leveled.
NOTE
: There are
no burner adjustments necessary on this range.
Figure 17
2.
Turn on Electrical Power and Open Main Shutoff
Gas Valve
3. Check the Igniters
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power. To check for proper lighting:
a. Push in and turn a surface burner knob to the LITE
position. All electronic surface ignitors will spark at the
same time. However, only the burner you are turning
on will ignite.
b. The surface burner should light once the flow of gas
reached the surface burner. Each burner should light
within four (4) seconds in normal operation after air
has been purged from supply lines. Visually check that
burner has lit.
c. Once the burner lights, the control knob should be
rotated out of the LITE position.
There are separate ignition devices for each burner. Try
each knob separately until all burner valves have been
checked.
Regular Burner
Burner Cap
Fixed Burner Ring
and Burner Base
Dual Surface
Burner
Burner Base
Fixed Burner Ring
Burner Cap
36” Range