Electrolux E36DF76GPS Installation Instructions - Page 4
Junction Box or Wall, Receptacle Location, Factory Connected Power, Supply Cord Canada only - dual fuel range
UPC - 057112098548
View all Electrolux E36DF76GPS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS (Model with Electric Oven and Gas Cooktop) 2. Factory Connected Power Supply Cord (Canada only) Your range is equipped with a factory-connected power cord (see Figure 3). Cord must be connected to a grounded 120/240 volt or 120/208 volt range outlet. If not outlet is available, have one installed by a qualified electrician. Figure 3 3. Junction Box or Wall Receptacle Location Suggested location of the junction box or wall receptacle is showed in Figure 4 for 30" Range and on figure 5 for 36" Range. It can also be located in the lower left corner of the adjacent right cabinet (see Figure 6). If a service cord is used, the wall receptacle should be located in accordance with the dimensions below. Center Line of Range 10" (25.4 cm) WALL 7" Max. (17.8 cm Max.) FLOOR Locate Electrical Hook-up Inside Shaded Area Center Line of Range 30" Range Junction Box or Wall Receptacle Location - Figure 4 Center Line of Range 10" (25.4 cm) WALL 5" Max. (12.7 cm Max.) FLOOR Locate Electrical Hook-up Inside Shaded Area Center Line of Range 36" Range Junction Box or Wall Receptacle Location - Figure 5 4. Power Supply Cord Kit (U.S.A.) The user is responsible for connecting the power supply cord to the connection block located behind the back panel access cover. This appliance may be connected by means of permanent "hard wiring" (flexible armored or nonmetallic shielded copper cable), or by means of a power supply cord kit. Use only a power supply cord kit rated at 125/250 volts minimum and marked for use with ranges. Cord must have either 3 or 4 conductors. Terminals on end of wires must either be closed loop or open-end spade lugs with upturned ends. Cord must have strain relief clamp. A 3-wire* or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (time-delay fuse or circuit breaker is recommended). DO NOT fuse neutral. The fuse size must not exceed the circuit rating of the appliance specified on the nameplate. For 30" or 36" Range: Use a power supply cord kit rated at 30A. * For mobile homes, new installations, recreational vehicles, or areas where local codes do not permit grounding through neutral, a 4 conductor power supply cord kit rated at 125/250 volts and marked for use with ranges should be used (see Figure 10). 8" (20.3 cm) 12" (30.5 cm) Figure 6 Electrical Shock Hazard • Electrical ground is required on this appliance. • Do not connect to the electrical supply until appliance is permanently grounded. • Disconnect power to the circuit breaker or fuse box before making the electrical connection. • This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance. • Do not use the gas supply line for grounding the appliance. Failure to do any of the above could result in a fire, personal injury or electrical shock. 4