Electrolux EFMG627UTT Complete Owners Guide English - Page 19

WARNING, IMPORTANT, Electrical connection, non-Canada - 3 wire cord

Page 19 highlights

Installation 19 Electrical connection (non-Canada) - 3 wire cord 3-wire receptacle (NEMA type 10-30R) WARNING ELECTRICAL SHOCK HAZARD Failure to disconnect power source before servicing could result in personal injury or even death. WARNING ELECTRICAL HAZARD Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 1. Turn off power supply to outlet. 2. Remove the screw securing the terminal block access cover in the lower corner on the back of the dryer. 3. Install a UL-approved strain relief according to the power cord/strain relief manufacturer's instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place. 4. Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief. 5. Attach the power cord neutral (center wire) conductor to the SILVER colored center terminal on the terminal block. Tighten the screw securely. 6. Attach the remaining two power cord outer conductors to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely. IMPORTANT If moving dryer from a 4-wire system and installing it in a 3-wire system, move the internal ground from the center terminal back to the GREEN screw next to the terminal block. 30 AMP NEMA 10-30 Neutral (center wire) Access Cover Screw Terminal Block Line 2 (BRASS Terminal) Neutral (SILVER Terminal) Line 1 (BRASS Terminal) Internal Ground (GREEN Screw) Install UL-Approved Strain Relief Here Terminal Screw Recovery Slot NOTE If a terminal screw falls during cord installation, it can be retrieved in the terminal screw recovery slot below the access panel. DO NOT remove internal ground in a 3-wire system!! Neutral terminal WARNING ELECTRICAL SHOCK HAZARD DO NOT make a sharp bend or crimp wiring/conductor at connections. 7. Follow manufacturer's guidelines for firmly securing the strain relief and power cord. 8. Reinstall the terminal block cover.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

19
Electrical connection
(non-Canada) - 3 wire cord
Installation
1. Turn off power supply to outlet.
2. Remove the screw securing the
terminal block access cover in the lower
corner on the back of the dryer.
3. Install a UL-approved strain relief
according to the power cord/strain relief
manufacturer’s instructions in the power
cord entry hole below the
access panel. At this time, the strain
relief should be loosely in place.
4. Thread an UNPLUGGED, UL-approved,
30 amp. power cord, NEMA 10-30 type
SRDT, through the strain relief.
5. Attach the power cord neutral (center
wire) conductor to the SILVER colored
center terminal on the terminal block.
Tighten the screw securely.
6. Attach the remaining two power cord
outer conductors to the outer, BRASS
colored terminals on the terminal block.
Tighten both screws securely.
3-wire receptacle
(NEMA type 10-30R)
Access
Cover Screw
Terminal
Block
Line 2
(BRASS Terminal)
Neutral
(SILVER Terminal)
Line 1
(BRASS Terminal)
Internal Ground
(GREEN Screw)
Install UL-Approved
Strain Relief Here
Terminal Screw
Recovery Slot
Neutral
(center wire)
30 AMP
NEMA 10-30
7. Follow manufacturer’s guidelines for
firmly securing the strain relief and
power cord.
8. Reinstall the terminal block cover.
DO NOT
remove
internal ground in
a 3-wire system!!
Neutral
terminal
NOTE
If a terminal screw falls during cord
installation, it can be retrieved in the
terminal screw recovery slot below the
access panel.
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source
before servicing could result in personal
injury or even death.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT
make a sharp bend or crimp
wiring/conductor at connections.
IMPORTANT
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the
internal ground from the center terminal
back to the GREEN screw next to the
terminal block.
WARNING
ELECTRICAL HAZARD
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.