Electrolux EI30EW35KW Product Specifications Sheet (English) - Page 8

Gas Cooktop Installation, Over 30/27 Electric Single Wall Oven

Page 8 highlights

Gas Cooktop Installation Over 30"/27" Electric Single Wall Oven For all approved gas cooktop models, a minimum height opening of 6-1/2" (from top of counter) required in right cabinet side panel and/or filler panel, to route gas and electric hookups. (Refer to Gas Cooktop Utility Hookup Diagram) Side filler panels necessary to isolate oven from adjoining cabinets. Panel height may need to be modified to accommodate the depth of approved gas cooktop models Electric Single Wall Oven Cutout For models: EW30EW55G, EI30EW35J, EW27EW55G & EI27EW35J Cooktop cutout** 120V/60Hz grounded outlet, for gas cooktop Approx. 3" 23 1/2 min.* 240 /208V Junction box for wall oven A Cooktop 18" max. Countertop Manifold pipe 61/2" min. 5" Flare union Flexible connector Pressure regulator 4" Gas Cooktop Utility Hookup Flare union 120V/60Hz grounded outlet Cabinet sides and/or filler panel Manual shutoff valve (Must be accessible) Oven cutout 36" min. 27 1/4" min. 28 1/4" max. Side View Cooktop Wall Oven 24" min. cutout depth Install 3/4" full plywood base on 2 runners, flush with toe plate, capable of supporting 200 lbs. (30" models) and 150 lbs. (27" models) Unit will overlap cutout (minimum) edges by 1" 4-1/2" maximum height allowed from oven base to floor if cooktop is installed directly over wall oven. To route armored cable to junction box through left cabinet side panel and/or filler panel, cut minimum 4" x 4" opening in wood base and runner (5" maximum height allowed with no cooktop.) *Critical dimension - MUST be applied **For cooktop cutout dimensions refer to model-specific product page or installation guide on web Cutout Width (A) 30" Wall 28 1/2" min. Oven 29" max. 27" Wall 24 7/8" min. Oven 25 1/4" max. 30" & 27" Electric Single Wall Ovens Under-Counter Installation Specifications • Product Weights - (EW30EW55G and EI30EW35J) 200 Lbs. / (EW27EW55G and EI27EW35J) 150 Lbs. • Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line. • Connected Load (kW Rating) @ 240 / 208 Volts = (30") 4.0 / 3.0 kW / (27") 3.4 / 2.6 kW • Amps @ 240 / 208 Volts = (30") 17.0 / 14.5 Amps / (27") 14.2 / 12.6 Amps • Recommended Circuit Breaker - 20 Amps • Always consult local and national electric codes. • Minimum 21" clearance for oven door depth when open. • Minimum 23-1/2" deep cutout dimension is critical for proper installation, to ensure that oven's faceplate will fit flush against cabinet front. • Full oven base of solid plywood or similar material required, capable of supporting 200 Lbs. (30" models) or 150 Lbs. (27" models). Install over two runners and flush with toe plate. • Base must be level and cabinet front must be square. • Allow 5" maximum height from oven base to floor, if NO cooktop is installed directly over wall oven. Gas Cooktop Installation Over 30" / 27" Electric Single Wall Oven Specifications Electrolux Single Wall Oven models EW30EW55G, EI30EW35J, EW27EW55G and EI27EW35J are approved to be used beneath Electrolux cooktop models EW36GC55G, EW30GC55G and EW30GC60I. For detailed Gas Cooktop installation, refer to model-specific product page and installation guide on web. • Side filler panels necessary to isolate oven from adjoining cabinets. Panel height may need to be modified to accommodate the depth of approved gas cooktop models. • Minimum height opening of 6-1/2" (from top of counter) required in right cabinet side panel and/or filler panel, to route gas and electric hookups. • Allow 4-1/2" maximum height from oven base to floor, if cooktop is installed directly over wall oven. Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions. Electrolux Major Appliances, N.A. USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) • electroluxappliances.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca GC_EW INST EL 10/10 © 2010 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in the U.S.A.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

30" & 27" Electric Single Wall Ovens
Under-Counter Installation Specifications
Product Weights – (EW30EW55G and EI30EW35J) 200 Lbs. /
(EW27EW55G and EI27EW35J) 150 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit fused
on both sides of line.
Connected Load (kW Rating) @ 240/208 Volts =
(30") 4.0/3.0kW / (27") 3.4/2.6kW
Amps @ 240/208 Volts =(30")17.0/14.5 Amps / (27")14.2/12.6 Amps
Recommended Circuit Breaker – 20 Amps
Always consult local and national electric codes.
Minimum 21" clearance for oven door depth when open.
Minimum 23-1/2" deep cutout dimension is critical for proper installation,
to ensure that oven’s faceplate will fit flush against cabinet front.
Full oven base of solid plywood or similar material required, capable
of supporting 200 Lbs. (30" models) or 150 Lbs. (27" models). Install
over two runners and flush with toe plate.
Base must be level and cabinet front must be square.
Allow 5" maximum height from oven base to floor, if NO cooktop is
installed directly over wall oven.
Gas Cooktop Installation Over
30"/27" Electric Single Wall Oven Specifications
Electrolux Single Wall Oven models EW30EW55G, EI30EW35J,
EW27EW55G and EI27EW35J are approved to be used beneath
Electrolux cooktop models EW36GC55G, EW30GC55G and EW30GC60I.
For detailed Gas Cooktop installation, refer to model-specific
product page and installation guide on web.
Side filler panels necessary to isolate oven from adjoining cabinets.
Panel height may need to be modified to accommodate the depth of
approved gas cooktop models.
Minimum height opening of 6-1/2"
(from top of counter)
required in right
cabinet side panel and/or filler panel, to route gas and electric hookups.
Allow 4-1/2" maximum height from oven base to floor, if cooktop is
installed directly over wall oven.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Gas Cooktop Installation
Over 30"/27" Electric Single Wall Oven
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-877-4electrolux (1-877-435-3287)
electroluxappliances.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
GC_EW INST EL
10/10
© 2010 Electrolux Home Products, Inc.
Printed in the U.S.A.
Oven cutout
120V/60Hz
grounded
outlet, for
gas cooktop
Cooktop
cutout**
27
1
/
4
" min.
28
1
/
4
" max.
240/208V
Junction box
for wall oven
Approx. 3"
To route armored cable to junction box through left
cabinet side panel and/or filler panel, cut minimum
4" x 4" opening in wood base and runner
*Critical dimension – MUST be applied
**For cooktop cutout dimensions refer to model-specific
product page or installation guide on web
5"
6
1
/
2
"
min.
Pressure regulator
Manual shutoff valve
(Must be accessible)
Cabinet sides
and/or filler panel
Flare union
Manifold
pipe
Flexible connector
Flare
union
4"
Countertop
18"max.
120V/60Hz
grounded outlet
Cooktop
Gas
Cooktop
Utility
Hookup
4-1/2" maximum height allowed
from oven base to floor if cooktop
is installed directly over wall oven.
(5" maximum height allowed
with no cooktop.)
Side View
Cooktop
Wall Oven
36"
min.
Cutout Width (A)
30" Wall
28
1
/
2
"min.
Oven
29"max.
27" Wall
24
7
/
8
"min.
Oven
25
1
/
4
"max.
24" min.
cutout depth
Electric Single Wall Oven Cutout
For models: EW30EW55G, EI30EW35J,
EW27EW55G & EI27EW35J
Unit will overlap cutout (minimum) edges by 1"
23
1
/
2
min.*
Install
3
/
4
" full plywood base on 2 runners,
flush with toe plate, capable of supporting
200 lbs. (30" models) and 150 lbs. (27" models)
A
For all approved gas cooktop models, a minimum
height opening of 6-1/2" (from top of counter) required
in right cabinet side panel and/or filler panel, to route
gas and electric hookups. (Refer to Gas Cooktop
Utility Hookup Diagram)
Side filler panels necessary to isolate oven from
adjoining cabinets. Panel height may need to
be modified to accommodate the depth of approved
gas cooktop models