Error Code E71 Fault Outlet Control Thermistor open circuit Outlet Control E72 Thermistor short circuit Possible Fault Conditions Outlet Control Thermistor or wiring defective Outlet Control Thermistor or wiring defective Possible Solutions Check resistance of Outlet Control Thermistor, and check wiring for open circuit. Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature (68-77° F or 20-25° C). Replace Outlet Control Thermistor and/or wiring and retest. Check resistance of Outlet Control Thermistor, and check wiring for short circuit across Thermistor connections. Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature (68-77° F or 20-25° C). Replace Outlet Control Thermistor and/or wiring and retest. E73 Inlet Control Thermistor open circuit Inlet Control Thermistor or wiring defective Check resistance of Inlet Control Thermistor, and check wiring for open circuit. Resistance should be between 47K Ohm and 66K Ohm at room temperature (68-77° F or 20-25° C). Replace Inlet Control Thermistor and/or wiring and retest. E74 Inlet Control Thermistor short circuit Inlet Control Thermistor or wiring defective Check resistance of Inlet Control Thermistor, and check wiring for short circuit across Thermistor connections. Resistance should be between 47K Ohm and 66K Ohm at room temperature (68-77° F or 20-25° C). Replace Inlet Control Thermistor and/or wiring and retest. E91 Communication Error Wiring, Electronic Control Board, or Check connections between Electronic Control Board and Interface Board. If no Interface Board defective wiring problems, replace Electronic Control Board or Interface Board. E92 Incompatible protocol Electronic Control Board incompatible with Interface Board Check if correct Interface Board console and Electronic Control Board are installed. Replace appropriate hardware. E93 Machine configuration Wrong configuration data loaded, Interface Board or Electronic Control Check if correct Interface Board and console are installed. Replace Interface Board and/or console. checksum error Board or wiring defective E94 Cycle configuration Wrong configuration data loaded or checksum error Electronic Control Board defective Replace Electronic Control Board. E97 Program mismatch Main Supply EA1 Frequency out of Range EA2 Voltage too high EA3 Voltage too low EA4 Improper home wiring Wrong configuration data loaded, Electronic Control Board defective Line frequency out of limits or Electronic Control Board faulty Line voltage too high or Electronic Control Board faulty Line voltage too low or Electronic Control Board faulty Line connections in home faulty, wiring or Electronic Control Board defective Replace Electronic Control Board. Check frequency of line voltage. Check amplitude of line voltage. Check amplitude of line voltage. Check wiring at terminal block for L1-N-L2 wired incorrectly. EA5 Main V Sensing failure Electronic Control Board defective Replace Electronic Control Board. High vent restriction, Exhaust Control Check vent restrictions and resistance values of Exhaust Control Thermistor EF1 Vent Blocked Thermistor, Inlet Control Thermistor, or and Inlet Control Thermistor. Electronic Control Board defective EF3 Max Timeout Timer Exhaust blocked; Exhaust Control Thermistor, Inlet Control Thermistor, Contact Sensor or Electronic Control Board defective Check vent restriction, Contact Sensor, and resistance values of Exhaust Control Thermistor and Inlet Control Thermistor EF8 Key Stuck Console button or Interface Board Check buttons for activation when pressed. Replace console or Interface Board defective as appropriate FACTORY RESET 1. Press and hold the "Temperature" and "Dryness" buttons simultaneously for 6 seconds. INSTALLATION CYCLE 1. Use the selector knob to select the "touch up" cycle 2. Press and hold the "my favorite" and "sanitize" buttons simultaneously for 6 seconds. 3. Remove any load from the dryer and press "start pause" to start installation cycle. DIAGNOSTIC MODE 1. Press the "cancel" button to enter standby mode and enable diagnostic entry. 2. Within 10 seconds after pressing "cancel", press any button (but "cancel") to wake up the control. 3. Within 5 seconds of wake up, turn the selector knob to the far left cycle and press and hold the "cancel" and the far left button under the display simultaneously for 3 seconds to enter the Diagnostic Mode. (note: to save time at wake up, the welcome screen can be bypassed by turning the selector knob). 4. Upon entering Diagnostic Mode, all lights should flash on and off. 5. The following steps can be cycled through by turning the selector knob clockwise: 2