Epson Stylus Pro 4000 Electrical Specification Input voltage range Rated frequency range Input frequency range Rated current Power consumption Description 90 to 264 V 50 to 60 Hz 49 to 61 Hz 1.0 A at 120 V 0.5 A at 220 V Approx. 50 W or less (ISO 10561 Letter Pattern) 15 W or less in standby mode 0.7 W or less in power off mode Mechanical Dimensions Width: 33.9 inches (848 mm) Depth: 30.5 inches (762 mm) Height: 14.8 inches (369 mm) Weight 88 lb (40 kg) without ink cartridges Environmental Temperature Operation: 50 to 95 °F (10 to 35 °C) Storage: -4 to 104 °F (-20 to 40 °C) 1 month at 104 °F (40 °C) Transit: -4 to 140 °F (-20 to 60 °C), stored in shipping container 120 hours at 140 °F (60 °C) Humidity (without condensation) Operation: 20 to 80% RH Storage: 20 to 85% RH Transit: 5 to 85% RH (stored in shipping container) Paper The allowable paper dimensions are shown below: Size Maximum external roll diameter Thickness Roll paper Cut sheets 8 to 17 in. (203 to 432 mm) wide 8 × 10 in. (203 x 254 mm) up to 17 x 22 in. (432 x 559 mm) 2 in. core: 4 in. (103 mm) - 3 in. core: 6 in. (150 mm) 3.15 to 19.7 mil (0.8 to 0.5 mm) 3.15 to 59 mil (0.8 to 1.5 mm) Notes: ❏ Poor quality paper may reduce print quality and cause paper jams and other problems. If you encounter problems, switch to a higher grade of paper. ❏ Do not use curled, folded, or deckle-edge paper, which cause paper jams. Store sheet media on a flat surface, in the original packaging. ❏ Unload roll paper from the paper path when not in use to prevent curling. ❏ For best results, use paper under the following conditions: Temperature: 59 to 77 °F (15 to 25 °C) Humidity: 40 to 60% RH Safety Approvals Safety standards UL 60950, CSA 22.2 No. 60950 EMC FCC Part 15 Subpart B, Class B, CSA C108.8 Class B Ink Cartridges Lightfastness* Color: up to 100 years Black and white: over 100 years Cartridge life Temperature 2 years from production date if unopened; within 6 months after opening package, at 77 °F (25 °C) Storage -22 to 104 °F (-30 to 40 °C); (uninstalled): 1 month at 104 °F (40 °C) Storage -4 to 104 °F (-20 to 40 °C); (installed): 1 month at 104 °F (40 °C) Transit: -22 to 140 °F (-30 to 60 °C); 1 month at 104 °F (40 °C), 120 hours at 140 °F (60 °C) Capacity Freezing: 5 °F (-15 °C); ink thaws and is usable after at least 3 hours at 77 °F (25 °C) 110 or 220 ml * Preliminary data from Wilhelm Imaging Research, Inc. indicate the lightfastness of color UltraChrome™ prints made by the Epson Stylus Pro 4000 printer will be rated up to 100 years under glass on specific Epson media. Data indicate the lightfastness of black and white UltraChrome™ images will be rated as greater than 100 years under glass on specific Epson media. Ink lightfastness ratings are based on accelerated testing of prints on specialty media, displayed indoors, under glass. Actual print stability will vary according to media, printed image, display conditions, light intensity, humidity, and atmospheric conditions. Epson does not guarantee longevity of prints. For maximum print life, display all prints under glass or lamination or properly store them. Visit www.wilhelm-research.com for the latest information. 2 - Epson Stylus Pro 4000 4/04

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Epson Stylus Pro 4000
2 - Epson Stylus Pro 4000
4/04
Electrical
Mechanical
Environmental
Paper
The allowable paper dimensions are shown below:
Notes:
Poor quality paper may reduce print quality and cause paper jams
and other problems. If you encounter problems, switch to a
higher grade of paper.
Do not use curled, folded, or deckle-edge paper, which cause
paper jams. Store sheet media on a flat surface, in the original
packaging.
Unload roll paper from the paper path when not in use to
prevent curling.
For best results, use paper under the following conditions:
Temperature:
59 to 77 °F (15 to 25 °C)
Humidity:
40 to 60% RH
Safety Approvals
Ink Cartridges
*
Preliminary data from Wilhelm Imaging Research, Inc. indicate the
lightfastness of color UltraChrome
prints made by the Epson Stylus
Pro 4000 printer will be rated up to 100 years under glass on specific
Epson media. Data indicate the lightfastness of black and white
UltraChrome™ images will be rated as greater than 100 years under
glass on specific Epson media.
Ink lightfastness ratings are based on accelerated testing of prints on
specialty media, displayed indoors, under glass. Actual print stability
will vary according to media, printed image, display conditions, light
intensity, humidity, and atmospheric conditions. Epson does not
guarantee longevity of prints. For maximum print life, display all prints
under glass or lamination or properly store them. Visit
www.wilhelm-research.com for the latest information.
Specification
Description
Input voltage range
90 to 264 V
Rated frequency range
50 to 60 Hz
Input frequency range
49 to 61 Hz
Rated current
1.0 A at 120 V
0.5 A at 220 V
Power consumption
Approx. 50 W or less (ISO 10561
Letter Pattern)
15 W or less in standby mode
0.7 W or less in power off mode
Dimensions
Width: 33.9 inches (848 mm)
Depth: 30.5 inches (762 mm)
Height: 14.8 inches (369 mm)
Weight
88 lb (40 kg) without ink cartridges
Temperature
Operation: 50 to 95 °F (10 to 35 °C)
Storage:
4 to 104 °F (
20 to 40 °C)
1 month at 104 °F (40 °C)
Transit:
4 to 140 °F (
20 to 60 °C),
stored in shipping container
120 hours at 140 °F (60 °C)
Humidity
(without
condensation)
Operation: 20 to 80% RH
Storage:
20 to 85% RH
Transit:
5 to 85% RH (stored in
shipping container)
Roll paper
Cut sheets
Size
8 to 17 in. (203 to
432 mm) wide
8 × 10 in.
(203 x 254 mm) up to
17 x 22 in.
(432 x 559 mm)
Maximum
external roll
diameter
2 in. core: 4 in. (103 mm)
3 in. core: 6 in. (150 mm)
Thickness
3.15 to 19.7 mil (0.8 to
0.5 mm)
3.15 to 59 mil (0.8 to
1.5 mm)
Safety standards
UL 60950, CSA 22.2 No. 60950
EMC
FCC Part 15 Subpart B, Class B,
CSA C108.8 Class B
Lightfastness*
Color: up to 100 years
Black and white: over 100 years
Cartridge life
2 years from production date if unopened;
within 6 months after opening package, at
77 °F (25 °C)
Temperature
Storage
22 to 104 °F (
30 to 40 °C);
(uninstalled): 1 month at 104 °F (40 °C)
Storage
4 to 104 °F (
20 to 40 °C);
(installed):
1 month at 104 °F (40 °C)
Transit
:
22 to 140 °F (
30 to 60 °C);
1 month at 104 °F (40 °C),
120 hours at 140 °F (60 °C)
Freezing:
5 °F (
15 °C); ink thaws and
is usable after at least 3 hours
at 77 °F (25 °C)
Capacity
110 or 220 ml