Epson H6000IIP User Manual - Page 133

select [No]. Do you want to set it to be a slave device ?

Page 133 highlights

Version 2.65 Jul. 2009 If selecting the [Yes] button, then the following message appears: "Logical Device Name "Unit 1" is used to refer to "TM-T88IVM". Do you want to replace it ?" 5. When changing a port causes an inconsistent Hydra state, the following message appears: "Device will not be set as COMn." 6. When trying to connect a device (slave device), which requires a master device, to a port by itself only, the following message appears: "No master device detected. You must set/add a proper master device for this device." 7. When changing the port of a master device with Hydra setting, the following message appears: "This device has been set as a master device. Hydra settings must be changed accordingly." 8. When trying to connect a new device to a port with Hydra configuration or which is connected to devices, if the new device is neither alone nor Hydra, then the following message appears: "Hydra connection detected for 'device name'. If the device is to be stand alone, select [No]. Do you want to set it to be a slave device ?" 9. When trying to connect a new device to a port connected to Hydra-configurable devices, if the devices which has limit of device which can connect and the device to fall outside the limit exist, then the following message appears: "The master device and the slave device combination is not proper. You must use this device under proper device combination. The changes to the serial port setting will be canceled." 10. The range of Hydra connection depends on the capability of the master device. When trying to add a new device to a port so that this operation exceeds the capability of the port, the following message appears: "Improper Hydra device(s) detected: Device will not be set as COMn." Note: The location of COMn, depending on the specified port, becomes LPTn, USBn or IP address/Host name. 128 User's Manual Installer, SetupPOS, TMUSB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

Version 2.65
Jul. 2009
128
User's Manual
Installer, SetupPOS, TMUSB
If selecting the [Yes] button, then the following message appears:
"Logical Device Name "Unit 1" is used to refer to "TM-T88IVM". Do you want
to replace it ?"
5. When changing a port causes an inconsistent Hydra state, the following message
appears:
"Device will not be set as COMn."
6. When trying to connect a device (slave device), which requires a master device,
to a port by itself only, the following message appears:
"No master device detected. You must set/add a proper master device for this
device."
7. When changing the port of a master device with Hydra setting, the following
message appears:
"This device has been set as a master device. Hydra settings must be changed
accordingly."
8. When trying to connect a new device to a port with Hydra configuration or which
is connected to devices, if the new device is neither alone nor Hydra, then the
following message appears:
"Hydra connection detected for 'device name'. If the device is to be stand alone,
select [No]. Do you want to set it to be a slave device ?"
9. When trying to connect a new device to a port connected to Hydra-configurable
devices, if the devices which has limit of device which can connect and the
device to fall outside the limit exist, then the following message appears:
"The master device and the slave device combination is not proper. You must
use this device under proper device combination. The changes to the serial port
setting will be canceled."
10. The range of Hydra connection depends on the capability of the master device.
When trying to add a new device to a port so that this operation exceeds the
capability of the port, the following message appears:
"Improper Hydra device(s) detected: Device will not be set as COMn."
Note: The location of COMn, depending on the specified port, becomes LPTn,
USBn or IP address/Host name.
<CheckHealth Interactive>