Page 68 highlights
send Forwards data to the Communication Box. Request Forwards messages to the Communication Box. Sub-element box_id message member_id Data type string string string Description Identifier of the Communication Box to forward the message to. Message to forward. Member ID to forward. To forward message to all the clients (applications) belonging to the Communication Box, specify " "(space). ❏ Example 3 send box1 send_message Response Returns the message transfer result. Sub-element box_id Data type string code string count string Description Identifier of the Communication Box that forwarded the message Forward result of the message. For details, refer to the code below. The number of clients that attempted to forward a message. ❏ code Element value "OK" "NOT_OPENED" "MEMBER_NOT_FOUND" "SYSTEM_ERROR" Description Successfully forwarded the message. A Communication Box is not open. The specified member ID cannot be found. System error occurred 68