Fisher and Paykel DE62T27CW2 AeroSmart LCD Models Installation Instructions &a - Page 30

Explosion Hazard

Page 30 highlights

28 Installation instructions Gas requirements (gas models only) The installation must conform with Local Codes, or in the absence of Local Codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. WARNING! Explosion Hazard Installations must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the state, province, or region where this appliance is being installed. Use a new AGA or CSA approved gas supply line. Install a shut-off valve in an accessible place. Only use a gas shut-off valve approved for use within the state, province, or region where this appliance is being installed. Securely tighten all gas connections. If connecting to LP Gas, have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column. Failure to follow these instructions can result in death, explosion, or fire. Gas type Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate located on the rear of the console. If this information does not agree with the type of gas available in your home, contact your local Fisher & Paykel supplier or service center. Natural gas This dryer is supplied ready for use with Natural Gas. It is design certified by UL International for LP (Propane or Butane) Gases with the appropriate conversion. LP gas conversion If the dryer is to be operated on LP (Liquid Propane or Butane) Gas, the dryer must be converted. To do so, use only the approved Fisher & Paykel conversion kit listed in Accessories on page 7. Do not use with a different gas without consulting the serving gas supplier. The dryer must be converted for safe and proper performance by qualified service or installation personel. Conversion kits for Natural and LP Gas are available from your local Fisher & Paykel Dealer (see Accessories page 7). If other conversions are required, check with your local gas utility for specific information concerning conversion requirements.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

28
Installation instructions
Gas requirements (gas models only)
The installation must conform with Local Codes, or in the absence of Local Codes, to the
National Fuel Gas Code ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane
Installation Code, CSA B149.1.
WARNING!
Explosion Hazard
Installations must be performed by a qualified or licensed contractor,
plumber, or gasfitter qualified or licensed by the state, province, or region
where this appliance is being installed.
Use a new AGA or CSA approved gas supply line.
Install a shut-off valve in an accessible place.
Only use a gas shut-off valve approved for use within the state, province, or
region where this appliance is being installed.
Securely tighten all gas connections.
If connecting to LP Gas, have a qualified person make sure gas pressure
does not exceed 13” (330 mm) water column.
Failure to follow these instructions can result in death, explosion, or fire.
Gas type
Your dryer must have the correct burner for the type of gas in your home. Burner information
is located on the rating plate located on the rear of the console. If this information does not
agree with the type of gas available in your home, contact your local Fisher & Paykel supplier or
service center.
Natural gas
This dryer is supplied ready for use with Natural Gas.
It is design certified by UL International for LP (Propane or Butane) Gases with the appropriate
conversion.
LP gas conversion
If the dryer is to be operated on LP (Liquid Propane or Butane) Gas, the dryer must be
converted. To do so, use only the approved Fisher & Paykel conversion kit listed in Accessories
on page 7. Do not use with a different gas without consulting the serving gas supplier.
The dryer must be converted for safe and proper performance by qualified service or installation
personel.
Conversion kits for Natural and LP Gas are available from your local Fisher & Paykel Dealer
(see Accessories page 7). If other conversions are required, check with your local gas utility for
specific information concerning conversion requirements.