Fluke 1000FLT Product Manual - Page 16

Pin Test, Table 6. Pin Test, Description

Page 16 highlights

Shop for Fluke products online at: www. 1000FLT Users Manual Pin Test The Pin Test feature checks the continuity of the filament between the pins. This is the default function when the Product is turned on. Make sure all other functions are off before you do a Pin Test.  should be the only button that is lit. To test (see Table 6): 1. Turn on the Product. 2. Insert the lamp pins into the slots on the Product . The green LED test indicator shows the filament is good . You will hear a continuous beep if it is on. No color on the LED test indicator shows that the filament is broken . Table 6. Pin Test 1 2 3 Item    LED no LED solid green no LED Description huz06.eps Ready for Pin Test, default mode Filament is good, continuous beep if the beeper is on Filament is broken MyFlukeStore.com 1.888.610.7664 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

1000FLT
Users Manual
10
Pin Test
The Pin Test feature checks the continuity of the filament
between the pins. This is the default function when the
Product is turned on.
Make sure all other functions are off before you do a Pin
Test.
should be the only button that is lit.
To test (see Table 6):
1.
Turn on the Product.
2.
Insert the lamp pins into the slots on the Product
.
The green LED test indicator shows the filament is
good
. You will hear a continuous beep if it is on.
No color on the LED test indicator shows that the
filament is broken
.
Table 6. Pin Test
huz06.eps
Item
LED
Description
no LED
Ready for Pin Test, default mode
solid green
Filament is good, continuous beep if the
beeper is on
no LED
Filament is broken
2
3
1
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore