Fluke 1000FLT Product Manual - Page 22

Specifications, Size H x W x L

Page 22 highlights

Shop for Fluke products online at: www. 1000FLT Users Manual Specifications Temperature Operating 10 °C to +50 °C (+14 °F to +122 °F) Storage 40 °C to +60 °C (-40 °F to +140 °F) Relative Humidity 85 % Operating Altitude 2000 m Battery Type 4 x AA Alkaline IEC LR6 Life 40 hr NCV (VoltAlert 85 V ac to 400 V ac 45 Hz to 67 Hz ≤10 cm (4 in) distance Pin Continuity Test 1 kΩ Ballast Test 20 kHz Ballast Type Electronic 20 kHz Magnetic 50 Hz to 60 Hz ≤3 m (10 ft) distance Drop 2 meter Size (H x W x L 21.5 cm x 3.0 cm x 6.5 cm (8.5 in x 1.2 in x 2.6 in) Weight 0.37 kg (0.80 lb) Warranty Main Body 3 years Rod Extender 1 year Safety IEC 61010-1, Pollution Degree 2 Electromagnetic Compatibility (EMC) EU IEC 61326-1 (Portable) CISPR 11, Group 2, Class A. Group 2 equipment contains all ISM RF equipment in which radio-frequency energy in the frequency range 9 kHz to 400 GHz is intentionally generated and used or only used, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purposes. Class A equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Caution, there may be potential difficulties in ensuring electromagnetic compatibility in other environments, due to conducted and radiated disturbances. US (FCC 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103 Applies to use in Korea only (KCC Class A Equipment (Industrial Broadcasting & Communication Equipment). This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. MyFlukeStore.com 1.888.610.7664 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

1000FLT
Users Manual
16
Specifications
Temperature
Operating
..........................
-10
°
C to +50
°
C (+14
°
F to +122
°
F)
Storage
.............................
-40
°
C to +60
°
C (-40
°
F to +140
°
F)
Relative Humidity
................
85 %
Operating Altitude
..............
<2000 m
Battery
Type
..................................
4 x AA Alkaline IEC LR6
Life
....................................
40 hr
NCV (VoltAlert
)
.................
85 V ac to 400 V ac
45 Hz to 67 Hz
10 cm (4 in) distance
Pin Continuity Test
.............
<1 k
Ω
Ballast Test
..........................
20 kHz
Ballast Type
Electronic
..........................
20 kHz
Magnetic
...........................
50 Hz to 60 Hz
3 m (10 ft) distance
Drop
.....................................
2 meter
Size (H x W x L)
...................
21.5 cm x 3.0 cm x 6.5 cm
(8.5 in x 1.2 in x 2.6 in)
Weight
..................................
0.37 kg (0.80 lb)
Warranty
Main Body
.........................
3 years
Rod Extender
....................
1 year
Safety
...................................
IEC 61010-1, Pollution Degree 2
Electromagnetic Compatibility (EMC)
EU
.....................................
IEC 61326-1 (Portable) CISPR 11, Group 2,
Class A.
Group 2 equipment contains all ISM RF
equipment in which radio-frequency energy
in the frequency range 9 kHz to 400 GHz is
intentionally generated and used or only
used, in the form of electromagnetic
radiation, inductive and/or capacitive
coupling, for the treatment of material or
inspection/analysis purposes.
Class A equipment is suitable for use in all
establishments other than domestic and
those directly connected to a low voltage
power supply network which supplies
buildings used for domestic purposes.
Caution, there may be potential difficulties in
ensuring electromagnetic compatibility in
other environments, due to conducted and
radiated disturbances.
US (FCC)
..........................
47 CFR 15 subpart B, this product is
considered an exempt device per clause
15.103
Applies to use in
Korea only (KCC)
..............
Class A Equipment (Industrial Broadcasting
& Communication Equipment).
This product meets requirements for
industrial (Class A) electromagnetic wave
equipment and the seller or user should
take notice of it. This equipment is intended
for use in business environments and not to
be used in homes.
Shop for Fluke products online at:
1.888.610.7664
www.