Fluke 199C/S FE 192,196,199 C Users Manual - Page 105

Trigger and Delay, Automatic Connect-and-View Trigger, Edge Trigger, Isolated External Trigger,

Page 105 highlights

FLUKE 192B: 10 ns to 2 µs /div up to 500 MS/s 5 µs to 120 s/div 20 MS/s Record Length Scope Record Mode ......... >27000 points on each input Scope Normal Mode 3000 points on each input Scope Glitch Capture Mode 300 min/max pairs on each input Glitch Detection 5 µs to 120 s/div......... displays glitches as fast as 50 ns Waveform Display A, B, A+B, A-B, A*B, A vs B Normal, Average (2,4,8,64 x), Persistence Time Base Accuracy 100 ppm + 0.04 div) Trigger and Delay Trigger Modes Automatic, Edge, External, Video, Pulse Width N-Cycle (C versions) Trigger Delay up to +1200 divisions Pre Trigger View one full screen length Max. Delay 12 seconds Automatic Connect-and-View Trigger Source A, B, EXT Slope Positive, Negative, Dual (C versions) 9 Specifications Dual Input Oscilloscope Edge Trigger Screen Update Free Run, On Trigger, Single Shot Source A, B, EXT Slope Positive, Negative, Dual (C versions) Trigger Level Control Range 4 divisions Trigger Sensitivity A and B DC to 5 MHz at >5 mV/div 0.5 divisions DC to 5 MHz at 2 mV/div and 5 mV/div ...........1 division 200 MHz (FLUKE 199B/C 1 division 250 MHz (FLUKE 199B/C 2 divisions 100 MHz (FLUKE 196B/C 1 division 150 MHz (FLUKE 196B/C 2 divisions 60 MHz (FLUKE 192B 1 division 100 MHz (FLUKE 192B 2 divisions Isolated External Trigger Bandwidth 10 kHz Modes Automatic, Edge Trigger Levels (DC to 10 kHz 120 mV, 1.2 V Video Trigger Standards PAL, PAL+, NTSC, SECAM Modes Lines, Line Select, Field 1 or Field 2 Source A Polarity Positive, Negative Sensitivity 0.7 division sync level 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122

Specifications
Dual Input Oscilloscope
9
97
FLUKE 192B:
10 ns to 2
µ
s /div
.................................
up to 500 MS/s
5
µ
s to 120 s/div
.............................................
20 MS/s
Record Length
Scope Record Mode
.........
>27000 points on each input
Scope Normal Mode
.............
300
0 points on each input
Scope Glitch Capture Mode
..............
300 min/max pairs
on each input
Glitch Detection
5
µ
s to 120 s/div
.........
displays glitches as fast as 50 ns
Waveform Display
.................
A, B, A+B, A-B, A*B, A vs B
Normal, Average (2,4,8,64 x), Persistence
Time Base Accuracy
......................
±(100 ppm + 0.04 div)
Trigger and Delay
Trigger Modes
........................................
Automatic, Edge,
External, Video, Pulse Width
N-Cycle (C versions)
Trigger Delay
.................................
up to +1200 divisions
Pre Trigger View
.............................
one full screen length
Max. Delay
......................................................
12 seconds
Automatic Connect-and-View Trigger
Source
..............................................................
A, B, EXT
Slope
.......................
Positive, Negative, Dual (C versions)
Edge Trigger
Screen Update
...........
Free Run, On Trigger, Single Shot
Source
...............................................................
A, B, EXT
Slope
......................
Positive, Negative, Dual (C versions)
Trigger Level Control Range
..........................
±
4 divisions
Trigger Sensitivity A and B
DC to 5 MHz at >5 mV/div
..........................
0.5 divisions
DC to 5 MHz at 2 mV/div and 5 mV/div
...........
1 division
200 MHz (FLUKE 199B/C)
..............................
1 division
250 MHz (FLUKE 199B/C)
............................
2 divisions
100 MHz (FLUKE 196B/C)
..............................
1 division
150 MHz (FLUKE 196B/C)
............................
2 divisions
60 MHz (FLUKE 192B)
....................................
1 division
100 MHz (FLUKE 192B)
................................
2 divisions
Isolated External Trigger
Bandwidth
.............................................................
10 kHz
Modes
....................................................
Automatic, Edge
Trigger Levels (DC to 10 kHz)
....................
120 mV, 1.2 V
Video Trigger
Standards
..............................
PAL, PAL+, NTSC, SECAM
Modes
......................
Lines, Line Select, Field 1 or Field 2
Source
............................................................................
A
Polarity
.................................................
Positive, Negative
Sensitivity
.......................................
0.7 division sync level