Fluke 287 Fluke 287 and 289 Multimeter Users Manual - Page 83
Capacitance and Diode Test Specifications, Function, Range, Resolution, Accuracy
View all Fluke 287 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
Capacitance and Diode Test Specifications Function Capacitance 1 nF [1] 10 nF [1] 100 nF [1] Range Resolution 0.001 nF 0.01 nF 0.1 nF 1 μF 0.001 μF 10 μF 0.01 μF Diode Test 100 μF 1000 μF 10 mF 100 mF 3.1 V 0.1 μF 1 μF 0.01 mF 0.1 mF 0.0001 V [1] With a film capacitor or better, using relative mode (REL Δ) to zero residual. True-rms Digital Multimeters Detailed Specifications Accuracy 1 % + 5 1 % + 5 1 % + 5 1 % + 5 1 % + 5 1 % + 5 1 % + 5 1 % + 5 2 % + 20 1 % + 20 73
True-rms Digital Multimeters
Detailed Specifications
73
Capacitance and Diode Test Specifications
Function
Range
Resolution
Accuracy
1 nF
[1]
0.001 nF
1 % + 5
10 nF
[1]
0.01 nF
1 % + 5
100 nF
[1]
0.1 nF
1 % + 5
1
μ
F
0.001
μ
F
1 % + 5
10
μ
F
0.01
μ
F
1 % + 5
100
μ
F
0.1
μ
F
1 % + 5
1000
μ
F
1
μ
F
1 % + 5
10 mF
0.01 mF
1 % + 5
Capacitance
100 mF
0.1 mF
2 % + 20
Diode Test
3.1 V
0.0001 V
1 % + 20
[1]
With a film capacitor or better, using relative mode (REL
Δ
) to zero residual.