Fluke 54-II-B Product Manual - Page 24

PK-1 Thermocouple (supplied with thermometer), Electrical, Weight, Dimensions, without, holster

Page 24 highlights

53IIB/54IIB Users Manual General Weight Dimensions (without holster) Battery Certification Safety 280 g (10 oz) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) 3 AA batteries P, ) CAN/CSA C22.2 No. 61010-1-04, ANSI/UL 61010-1:2004, EN/IEC 61010-1:2001 EMC EN/IEC 61326-1:2006 CAT I OVERVOLTAGE (Installation) CATEGORY I, Pollution Degree 2 per IEC1010-1* * Refers to the level of Impulse Withstand Voltage protection provided. Category 1 products should not be attached to mains circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Type K, Chromel Alumel, bead style Temperature Range Accuracy -40 oC to +260 oC (-40 oF to +500 oF) ±1.1 oC (±2.0 oF) Electrical Measurement Range Display Resolution J-type: -210 oC to +1200 oC (-346 oF to +2192 oF) K-type: -200 oC to +1372 oC (-328 oF to +2501 oF) T-type: -250 oC to +400 oC (-418 oF to +752 oF) E-type: -150 oC to +1000 oC (-238 oF to +1832 oF) N-type: -200 oC to +1300 oC (-328 oF to +2372 oF) R- and S-type: 0 oC to +1767 oC (+32 oF to +3212 oF) 0.1 oC / oF / K

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

53IIB/54IIB
Users Manual
20
General
Weight
280 g (10 oz)
Dimensions
(without
holster)
2.8 cm
×
7.8 cm
×
16.2 cm
(1.1 in
×
3 in
×
6.4 in)
Battery
3 AA batteries
Certification
P
,
)
Safety
CAN/CSA C22.2 No. 61010-1-04, ANSI/UL
61010-1:2004, EN/IEC 61010-1:2001
EMC
EN/IEC 61326-1:2006
CAT I
OVERVOLTAGE (Installation) CATEGORY
I, Pollution Degree 2 per IEC1010-1*
*
Refers to the level of Impulse Withstand Voltage protection
provided. Category 1 products should not be attached to mains
circuits.
80 PK-1 Thermocouple (supplied with
thermometer)
Type
Type K, Chromel Alumel, bead style
Temperature
Range
-40
o
C to
+
260
o
C
(-40
o
F to
+
500
o
F)
Accuracy
±
1.1
o
C (
±
2.0
o
F)
Electrical
Measurement
Range
J-type: -210
o
C to
+
1200
o
C
(-346
o
F to
+
2192
o
F)
K-type: -200
o
C to
+
1372
o
C
(-328
o
F to
+
2501
o
F)
T-type: -250
o
C to
+
400
o
C
(-418
o
F to
+
752
o
F)
E-type: -150
o
C to
+
1000
o
C
(-238
o
F to
+
1832
o
F)
N-type: -200
o
C to
+
1300
o
C
(-328
o
F to
+
2372
o
F)
R- and S-type: 0
o
C to
+
1767
o
C
(
+
32
o
F to
+
3212
o
F)
Display
Resolution
0.1
o
C /
o
F / K
<
1000
o
1.0
o
C /
o
F / K
1000
o
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com