Fluke 831 Product Manual - Page 32
Dimensions, Setup / Train Fixation screen.
View all Fluke 831 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
On-board help Dimensions From the home screen, tap screen. the horizontal alignment icon to access the dimensions l (1) Grayed out icons are disabled within the active screen. The 'Measure' icon is enabled after all dimensions have been entered. l (2) Tap the measurement units icon between "inch" and "mm". to set desired units. The icon toggles l (3) Tap the slider on the mini train icon to open the triple "Train Manager" / "Train Setup" / "Train Fixation" screen. Note: "Train Manager" is not active. See section on train setup and fixation for details. Tap the dimension fields and enter all required dimensions. The user may elect to tap the 'Next' button to proceed to enter next dimension. Dimensions may be entered only when the dimension field is highlighted blue. Note If units are set to Imperial system, inch fractions may be entered as follows: For 1/8" enter 1/8 = 0.125"; For 10 3/8" enter 10 + 3/8 = 10.375". The coupling diameter value may be determined by entering the measured cir- cumference of the coupling and dividing the value by π (pi) (= 3.142). For example 33"/π = 10.5"; Or 330 mm/π = 105 mm The rotate machine view icon ponents on the display. is used to rotate the view of the machines and mounted com- Machine and coupling properties may be edited by tapping the respective machine or coupling. When all required dimensions have been entered, the 'Measure' icon comes into view. MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664