TiS55+/TiS75+ Users Manual Basic Operation Turn On and Off the Product Before you use the Product for the first time, charge the battery. See Charge Batteries. To turn on the Product, push and hold O for 1 second. To turn off the Product, push and hold O for 2 seconds. Note All thermal Imagers need sufficient warm-up time for accurate temperature measurements and best image quality. Warm-up time can vary by model and environmental conditions. Although most Imagers are fully warmed up in 3 minutes to 5 minutes, wait a minimum of 10 minutes if the most accurate temperature measurement is important to your application. When you move an Imager between environments with large differences in ambient temperature, allow for additional adjustment time. Focus Correct focus makes sure that the infrared energy is correctly directed onto the pixels of the detector. Without correct focus, the thermal image can be blurry and the radiometric data may be inaccurate. Out-of-focus infrared images are frequently unusable or of little value. To focus with the advanced manual focus system, rotate the Manual Focus Control until the inspection object is in proper focus. To simulate fixed focus at 1.2 m, align the raised bar on the focus control with the marker on the case. See Figure 1. Figure 1. Fixed Focus 1.2 m 8 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664